Description
Woodward 8440-1936 easYgen-3500 Generator Paralleling & Genset Controller
Product Title
Woodward 8440-1936 | easYgen-3500 Digital Genset Controller, Synchronization & Load Sharing Unit for Diesel / Gas Generator Sets
Product Description
8440-1936 is Woodward easYgen-3500 series panel mount genset integrated controller. It is designed for single or multiple generator paralleling applications, combining engine speed governing, generator voltage regulation, automatic synchronizing, real & reactive power load sharing, breaker control and comprehensive generator protection inside one unit. It features color LCD display + soft keys for local operation, status viewing and parameter setup. It supports peak shaving, standby power, CHP cogeneration and island/grid-connected mode. It can communicate via Modbus RTU, Ethernet and CAN bus to connect with PLC, SCADA or other Woodward engine controls. It is widely used for diesel & gas gen-sets from 5~50MW in power plants, oil & gas, data center and industrial backup power systems.
Technical Specifications
| Item | Parameter |
|---|---|
| Brand | Woodward (伍德沃德) |
| Model | 8440-1936, easYgen-3500 |
| Mounting | Panel mount |
| Power Supply | 8–40 VDC (12/24 VDC nominal) |
| Operating Temperature | -20°C ~ +70°C |
| Discrete Inputs | Up to 23 digital inputs |
| Discrete Outputs | Up to 22 configurable relay outputs |
| Analog Input | 8 × 4–20mA |
| Analog Output | 4 × 4–20mA |
| Speed Input | Magnetic / optical tachometer sensor |
| Communication | Modbus RTU, Ethernet, CAN bus |
| Control Functions | Synchronization, kW / kVAR load sharing, droop / isochronous control, auto start-stop, breaker management |
| Protection | Over/under frequency, over/under voltage, overcurrent, reverse power, loss of excitation, engine protection |
| Display | Color LCD with soft keys |
| Frequency Accuracy | ±0.1% |
| Certifications | CE, UL |
| Enclosure Rating | Front IP65, rear IP20 |
Compatibility & Installation Pitfalls
Compatibility
- Engine types: Diesel engine, natural gas / biogas engine genset
- Other Woodward controls: 505, 505E, other easYgen controllers via CAN / analog
- Host: PLC, SCADA via Modbus / Ethernet
- Sensors: Magnetic pickup speed sensor, CT/PT for generator power measurement
- Not compatible: Older easYgen-2000, DSLC / DTSC standalone load sharing modules (different architecture)
Critical Installation Pitfalls
- CT & PT wiring safety: Current transformer secondary terminals must be shorted before disconnecting; open CT circuit generates lethal high voltage.
- Synchronization configuration: Voltage, frequency and phase matching parameters must be correctly configured before paralleling, otherwise serious damage to generator.
- EMI isolation: Keep controller away from inverter, welding and high-power cables. Strong electromagnetic interference causes sampling drift and false trips.
- Backup configuration file: Save full application parameter file before replacement. Without backup, all paralleling and protection settings must be reconfigured.
- Power supply: Use clean, surge-protected 12/24 VDC battery supply. Do not share with large engine starter loads to avoid voltage drop and controller reset.
- Panel gasket: Keep front sealing gasket installed to maintain IP65 protection against dust and condensation.
- Not hot-swappable: Power down and lock out before removal. Live removal causes loss of genset protection and paralleling control.
Standard Operating Procedure (SOP)
- Pre-Install Inspection & LOTO Execute LOTO for generator high voltage and DC control power. Inspect LCD, keypad and rear terminal blocks, verify part number 8440-1936. Prepare easYgen configuration software.
- Panel Mounting Install controller into control cabinet panel cutout, fit front gasket and fasten mounting clips.
- CT/PT, Sensor & Communication Wiring Wire CT, PT, tachometer, digital inputs/outputs and 24VDC power. Connect Modbus/Ethernet/CAN communication cables. Use shielded twisted pair and perform insulation/continuity test.
- Controller Programming & Configuration Use easYgen PC software or front keypad: set genset rated parameters, synchronizing window, load sharing mode, protection thresholds, breaker logic. Save configuration file.
- Power-Up & Commissioning Apply DC control power. Verify voltage/current/frequency readings. Complete dead bus test, then no-load synchronizing test and load sharing test. Validate all alarm & protection functions.
- Runtime Operation & Diagnostics Monitor genset status, power, alarms via front screen or SCADA. Regularly backup parameter file.
- Replacement Procedure Execute LOTO. Disconnect CT shorting links first, then all wiring. Remove old controller. Install spare 8440-1936, rewire, restore saved configuration, perform full commissioning and protection verification.
Application Scenarios
- Multi-generator parallel power plant
- Oil & gas site prime / backup power
- CHP combined heat and power units
- Data center critical standby power
- Industrial island power & peak shaving
- Marine power generation system
- Retrofit and spare replacement for existing easYgen-3500 genset control systems
Supporting Components
- Panel mounting hardware & sealing gasket
- Current transformer CT & voltage transformer PT
- Magnetic pickup speed sensor
- 12/24 VDC industrial battery power supply with surge protection
- easYgen configuration PC software
- Shielded twisted pair for analog / communication wiring
- Circuit breakers and terminal blocks
- Engine protection sensors (temperature, pressure)
- PLC / SCADA host for remote monitoring
- Woodward CAN bus communication cables
Related Model Recommendations (10 Models)
- Woodward easYgen-3500 series variants
- Woodward 8440-2299 DSLC-2XT load sharing controller
- Woodward 505 / 505E turbine governor
- Woodward 8440-2297 DTSC-200A synchronizer
- CLS216 Watlow multi-loop temperature controller
- CLS204 Watlow 4-loop temperature controller
- WAGO 758-873 PFC200 PLC
- MCS2000-ECA Warner tension controller
- VM600 MPC4 Vibro-Meter vibration protection card
- IPC704 244-704-000-042-A2-B01-C10 eddy current conditioner