Allen‑Bradley 1746‑NO4I SLC 500 4‑Channel Analog Current Output Module

Recommended Related Part Numbers

  • 1746‑NO4V: 4‑channel analog voltage output
  • 1746‑NI4: 4‑channel differential analog input
  • 1746‑NI8: 8‑channel single‑ended analog input
  • 1746‑NIO4I / NIO4V: Analog combination I/O
  • 1747‑ASB: Remote I/O adapter
  • 1747‑L552: SLC 5/05 processor
  • 1746‑A7 / 1746‑A10: SLC chassis
Category: Brand:

Description

Allen‑Bradley 1746‑NO4I SLC 500 4‑Channel Analog Current Output Module

 

Meta Description

Original Allen‑Bradley 1746‑NO4I SLC 500 4-channel analog current output module, 4‑20mA / 0‑20mA, isolated analog output, discontinued legacy SLC analog spare. We operate 86 shared warehouses globally, so it may take several hours to deliver an accurate quotation; thank you for your understanding, and we will handle your inquiry promptly.

1746-NO4I

Product Brief Introduction

The 1746‑NO4I is a single‑slot 4‑channel analog current output module for Allen‑Bradley SLC 500 PLC systems. It converts digital values from the SLC processor into analog current signals, mainly for 0‑20mA and 4‑20mA control loops, to drive valve positioners, variable frequency drives, indicators and other analog field actuators. Each channel is independently configurable, with isolation design to reduce interference between the rack side and field side. It is widely used in process control for regulating flow, pressure, temperature and level. Rockwell has discontinued the 1746‑NO4I; stock is limited for maintenance and spare replacement of legacy process control systems. We operate 86 shared warehouses globally, so it may take several hours to deliver an accurate quotation; thank you for your understanding, and we will handle your inquiry promptly.

 

Main Technical Specifications

  • Part Number: 1746‑NO4I
  • Manufacturer: Allen‑Bradley / Rockwell Automation
  • Platform: SLC 500
  • Type: Analog Current Output Module
  • Channel Count: 4 channels
  • Selectable Output Ranges: 0‑20mA, 4‑20mA
  • Resolution: 12‑bit
  • Accuracy: ±0.5% full scale
  • Slew Rate: Adjustable
  • Backplane Current Draw: 150 mA @ 5.1 VDC
  • Isolation: 500VAC between backplane and field side
  • Indicators: Module power LED
  • Operating Temperature: 0 °C to +60 °C
  • Storage Temperature: −40 °C to +85 °C
  • Relative Humidity: 5–95 %, non‑condensing
  • Certifications: UL, cULus, CE
  • Lifecycle Status: Discontinued
  • Warranty: 1 year
  • Compatibility: Local chassis and remote I/O racks with 1747‑ASB adapter

 

Quality Control Procedure

Each 1746‑NO4I analog output module undergoes precision calibration test. We inspect housing, terminal block, DIP switch and label integrity. Functional testing reads the output current of each channel under different set values, verifying linearity, stability and accuracy. Channels with drift, unstable output or failure to reach full scale are rejected. Passed modules are packed with anti‑static shielding, and test records are retained for traceability. Please note if you submit a quote request: We operate 86 shared warehouses globally, so it may take several hours to deliver an accurate quotation; thank you for your understanding, and we will handle your inquiry promptly.

 

FAQ

A: It is a 4‑channel analog current output module for SLC 500, used to output 4‑20mA / 0‑20mA control signals for valves and transmitters.

A: = current output (0‑20mA / 4‑20mA); NO4V = voltage output (0‑10V / ±10V).

Q: Can it be used in remote I/O racks? A: Yes, compatible with local chassis and remote racks controlled by 1747‑ASB.

Q: Is this module still in production? A: No, Rockwell discontinued this part. Stock is limited surplus inventory only.

Q: When will I receive my quotation? A: We operate 86 shared warehouses globally, so it may take several hours to deliver an accurate quotation; thank you for your understanding, and we will handle your inquiry promptly.

 

Installation & Configuration Guide

Slide the 1746‑ into an empty slot of a 1746 chassis and lock the latch. Set DIP switches to select the output range for each channel before wiring. Wire the field actuators to the corresponding current output terminals. Power up the rack and field equipment. In RSLogix 500, add the analog module and configure scaling for control setpoints. Follow Rockwell’s official manual and local electrical codes.

 

Relevant News & Events

The 1746‑ is a classic current output card for SLC process control, common in water treatment, chemical, heating and packaging lines for analog closed‑loop regulation. As SLC analog I/O is end‑of‑life, functional tested spare cards are in steady demand for plant maintenance. The recommended migration solution is Compact 5000 analog output with CompactLogix controllers.

 

Application Scenarios & Functional Advantages

Typical Use Cases

  • 4‑20mA control for pneumatic control valves and valve positioners
  • Analog setpoint signals for VFDs and display indicators
  • Process regulation of temperature, pressure, flow and liquid level
  • SLC 500 remote I/O analog control expansion
  • Replacement spare for failed 4-channel analog current output cards

Key Advantages

  • 4 independent current output channels, standard 4‑20mA process signal
  • Galvanic isolation reduces interference between PLC and field devices
  • Adjustable slew rate to avoid sudden signal jumps
  • Supported in local and remote SLC I/O racks
  • Mature, widely proven design for legacy process sites
  • Simple DIP switch range selection

 

Recommended Related Part Numbers

  • 1746‑NO4V: 4‑channel analog voltage output
  • 1746‑NI4: 4‑channel differential analog input
  • 1746‑NI8: 8‑channel single‑ended analog input
  • 1746‑NIO4I / NIO4V: Analog combination I/O
  • 1747‑ASB: Remote I/O adapter
  • 1747‑L552: SLC 5/05 processor
  • 1746‑A7 / 1746‑A10: SLC chassis