Allen‑Bradley 1746‑NR4 SLC 500 4‑Channel RTD / Resistance Input Module

 

Meta Description

Original Allen‑Bradley 1746‑NR4 SLC 500 4-channel RTD temperature and resistance input module, support 2/3/4-wire Pt100, Ni, Cu sensors, broken wire detection, discontinued legacy temperature spare. We operate 86 shared warehouses globally, so it may take several hours to deliver an accurate quotation; thank you for your understanding, and we will handle your inquiry promptly.

Product Brief Introduction

The 1746‑NR4 is a single‑slot 4‑channel RTD/resistance input module for Allen‑Bradley SLC 500 PLC systems. It is specially designed for temperature measurement with RTD sensors, supporting platinum, nickel, copper and nickel‑iron RTDs, as well as general resistance inputs and potentiometer signals. Each channel can be independently configured for 2‑wire, 3‑wire or 4‑wire connection modes. It supports direct conversion to °C / °F or resistance value in ohms, and provides open‑circuit and short‑circuit fault diagnosis for each channel. Widely used in furnace, oven, water treatment, food and pharmaceutical temperature monitoring. Rockwell has discontinued the 1746‑NR4; stock is limited for maintenance and spare replacement of legacy temperature control systems. We operate 86 shared warehouses globally, so it may take several hours to deliver an accurate quotation; thank you for your understanding, and we will handle your inquiry promptly.

 

Main Technical Specifications

  • Part Number: 1746‑NR4
  • Manufacturer: Allen‑Bradley / Rockwell Automation
  • Platform: SLC 500
  • Type: RTD / Resistance Temperature Input Module
  • Channel Count: 4 channels
  • Supported Sensor Types: Pt100, Pt1000, Nickel, Copper, Nickel‑Iron RTDs
  • Wiring Mode: 2‑wire / 3‑wire / 4‑wire configurable per channel
  • Diagnostics: Open circuit, short circuit, out‑of‑range alarm per channel
  • Backplane Current Draw: 50 mA @5.1VDC, 50mA @24VDC
  • Isolation: 500VAC between backplane and field side
  • Indicators: Module power LED
  • Operating Temperature: 0 °C to +60 °C
  • Storage Temperature: −40 °C to +85 °C
  • Relative Humidity: 5–95 %, non‑condensing
  • Certifications: UL, cULus, CE
  • Lifecycle Status: Discontinued, engineering replacement required
  • Warranty: 1 year
  • Compatibility: Local chassis and remote I/O racks with 1747‑ASB adapter

 

Quality Control Procedure

Each 1746‑NR4 temperature module undergoes precision resistance calibration test. We inspect housing, removable terminal block and label integrity. Functional testing uses standard resistance simulators to simulate different RTD values, verify temperature reading accuracy, linearity and fault alarm function. Channels with drift, reading jump or failed wire break detection are rejected. Passed modules are packed with anti‑static shielding, and test records are retained for traceability. Please note if you submit a quote request: We operate 86 shared warehouses globally, so it may take several hours to deliver an accurate quotation; thank you for your understanding, and we will handle your inquiry promptly.

 

FAQ

Q: What is 1746‑NR4? A: It is a 4‑channel RTD temperature input module for SLC 500, used for Pt100 and other resistance temperature sensors.

Q: What is the difference between NR4 and NR8? A: NR4 = 4 RTD channels; NR8 = 8 RTD channels, higher density for multi‑point temperature collection.

Q: Can it support 3‑wire Pt100? A: Yes, each channel can be set to 2/3/4‑wire mode in software configuration.

Q: Can it detect broken RTD wires? A: Yes, built‑in open/short circuit fault detection for each channel.

Q: Can it be used in remote I/O racks? A: Yes, compatible with local chassis and remote racks controlled by 1747‑ASB.

Q: Is this module still in production? A: No, Rockwell discontinued this part. Stock is limited surplus inventory only.

Q: When will I receive my quotation? A: We operate 86 shared warehouses globally, so it may take several hours to deliver an accurate quotation; thank you for your understanding, and we will handle your inquiry promptly.

 

Installation & Configuration Guide

Slide the 1746‑NR4 into an empty slot of a 1746 chassis and lock the latch. Wire RTD sensors following selected 2/3/4‑wire wiring diagram. Power up the rack. In RSLogix 500, configure sensor type, wiring mode and temperature unit (°C / °F) for each channel, the module supports onboard scaling. Follow Rockwell manual 1746‑UM008 and local electrical codes.

 

Relevant News & Events

The 1746‑NR4 is a classic dedicated temperature card for SLC 500, widely used in legacy thermal process lines. Since it is a special RTD module different from general voltage/current analog NI4, spare parts are more scarce. The recommended migration solution is Compact 5000 RTD I/O with CompactLogix controllers.

 

Application Scenarios & Functional Advantages

Typical Use Cases

  • Pt100 / Pt1000 temperature monitoring for tanks, pipelines, furnaces and ovens
  • Food, pharmaceutical, water treatment and HVAC temperature control
  • Resistance signal and potentiometer value acquisition
  • SLC 500 remote I/O temperature expansion
  • Replacement spare for failed 4‑channel RTD input cards

Key Advantages

  • 4 independent RTD channels, mix of sensor types and wiring modes
  • Built‑in wire break / short circuit fault diagnosis
  • Direct temperature conversion, no extra scaling logic required
  • Support 2,3,4 wire to reduce wiring resistance error
  • Supported in local and remote SLC I/O racks
  • Mature, stable design for legacy thermal process sites

 

Recommended Related Part Numbers

  • 1746‑NR8: 8‑channel RTD input module
  • 1746‑NI4: 4‑channel voltage/current analog input
  • 1746‑NO4I / NO4V: Analog output modules
  • 1747‑ASB: Remote I/O adapter
  • 1747‑L552: SLC 5/05 processor
  • 1746‑A7 / 1746‑A10: SLC chassis