Description
Allen‑Bradley 1746‑NI4 SLC 500 4‑Channel Differential Analog Input Module
Meta Description
Original Allen‑Bradley 1746‑NI4 SLC 500 4-channel differential analog input module, multi-range voltage/current, 16-bit resolution, discontinued legacy analog spare. We operate 86 shared warehouses globally, so it may take several hours to deliver an accurate quotation; thank you for your understanding, and we will handle your inquiry promptly.

1746-NI4
Product Brief Introduction
The 1746‑NI4 is a single‑slot 4‑channel differential analog input module for Allen‑Bradley SLC 500 PLC systems. It converts analog voltage or current field signals into digital 16‑bit values for the SLC processor. Each channel can be independently configured via DIP switch for different signal ranges, supporting both voltage and 4‑20mA/0‑20mA transmitters. Differential design improves noise immunity, ideal for pressure, temperature, flow and level transmitters. Rockwell has discontinued the 1746‑NI4; stock is limited for maintenance and spare replacement of legacy process control systems. We operate 86 shared warehouses globally, so it may take several hours to deliver an accurate quotation; thank you for your understanding, and we will handle your inquiry promptly.
Main Technical Specifications
- Part Number: 1746‑NI4
- Manufacturer: Allen‑Bradley / Rockwell Automation
- Platform: SLC 500
- Type: Analog Input Module
- Channel Count: 4 differential channels
- Selectable Signal Ranges: ±10V, 0‑10V, 0‑5V, 1‑5V, 0‑20mA, 4‑20mA
- Resolution: 16-bit
- Update Time: 5 ms per channel
- Accuracy: ±0.1% full scale
- Backplane Current Draw: 110 mA @ 5.1 VDC
- Isolation: 500VAC between backplane and field side
- Indicators: Module power LED
- Operating Temperature: 0 °C to +60 °C
- Storage Temperature: −40 °C to +85 °C
- Relative Humidity: 5–95 %, non‑condensing
- Certifications: UL, cULus, CE
- Lifecycle Status: Discontinued
- Warranty: 1 year
- Compatibility: Local chassis and remote I/O racks with 1747‑ASB adapter
Quality Control Procedure
Each 1746‑NI4 analog module undergoes our analog calibration test workflow. We inspect housing, terminal block, DIP switch and label integrity. Functional testing injects precision voltage and current signals to all 4 channels, verify raw counts, linearity and stability, confirm backplane communication. Units with drift, dead channels or unstable readings are rejected. Passed modules are packed with anti‑static shielding, and test records are retained for traceability. Please note if you submit a quote request: We operate 86 shared warehouses globally, so it may take several hours to deliver an accurate quotation; thank you for your understanding, and we will handle your inquiry promptly.
FAQ
Q: What is 1746‑NI4? A: It is a 4-channel differential analog input module for SLC 500, used for 4‑20mA transmitters and analog voltage signals.
Q: What is the difference between NI4 and NI8? A: NI4 = 4 differential channels, better anti‑noise; NI8 = 8 single‑ended channels, higher density.
Q: Can it support 4‑20mA sensors? A: Yes, select 4‑20mA range by DIP switch on each channel.
Q: Can it be used in remote I/O racks? A: Yes, compatible with local chassis and remote racks controlled by 1747‑ASB.
Q: Is this module still in production? A: No, Rockwell discontinued this part. Stock is limited surplus inventory only.
Q: When will I receive my quotation? A: We operate 86 shared warehouses globally, so it may take several hours to deliver an accurate quotation; thank you for your understanding, and we will handle your inquiry promptly.
Installation & Configuration Guide
Slide the 1746‑NI4 into an empty slot of a 1746 chassis and lock the latch. Set DIP switches for each channel’s signal range before wiring. Wire transmitters to differential input terminals. Power up the rack and field transmitter supply. In RSLogix 500, add the analog module and configure scaling for engineering units. Follow Rockwell’s manual 1746‑IN008 and local electrical codes.
Relevant News & Events
The 1746‑NI4 is a widely used analog card for SLC 500 process applications, water treatment, chemical and packaging lines with analog transmitters. Differential input makes it popular for long sensor cables. As SLC analog I/O reaches end‑of‑life, good working units are in high demand for plant maintenance. The recommended migration path is Compact 5000 analog I/O with CompactLogix.
Application Scenarios & Functional Advantages
Typical Use Cases
- 4‑20mA pressure, temperature, flow and level transmitters
- Analog voltage signals from potentiometers, sensors and instruments
- Water & wastewater, chemical and packaging process control panels
- SLC 500 remote I/O analog expansion
- Replacement spare for failed 4-channel differential analog input cards
Key Advantages
- 4 differential channels, strong noise suppression for long sensor cables
- Multi-range selection, supports both voltage and current transmitters
- High 16-bit resolution for precise measurement
- Supported in local and remote SLC I/O racks
- Stable and proven design for legacy process sites
- Simple DIP switch configuration per channel
Recommended Related Part Numbers
- 1746‑NI8: 8-channel single-ended analog input
- 1746‑NO4I: 4-channel analog current output
- 1746‑NO4V: 4-channel analog voltage output
- 1746‑NIO4I / NIO4V: Combo analog I/O
- 1747‑ASB: Remote I/O adapter
- 1747‑L552: SLC 5/05 processor
- 1746‑A7 / 1746‑A10: SLC chassis