Description
WATLOW ANAFAZE CLS216 CAS200 | 16-Loop Multi-Point Temperature Controller, CLS200 Series
Product Description
CLS216 (CAS200 platform) is Watlow Anafaze high-performance 16 independent loop multi-point temperature controller, belongs to CLS200 compact loop system family. It accepts universal sensor inputs including thermocouple, RTD, mV, mA and voltage signals. It executes PID auto-tune, ramp & soak batch curve control, cascade / ratio / differential control for thermal processes. Equipped with a 32-character VFD vacuum fluorescent display and 8-key front keypad. It supports Modbus RTU, RS232 / RS485 serial communication for SCADA / PLC host connection. It can store up to 8 batch recipes. Digital time-proportional outputs drive solid-state relays or contactors for heating/cooling regulation, widely used for furnaces, thermal treatment, extrusion, oven and semiconductor thermal process control.
Technical Specifications
| Item | Parameter |
|---|---|
| Brand | WATLOW ANAFAZE |
| Model | CLS216 (CAS200 / CLS200 series) |
| Control Loops | 16 independent control loops |
| Input Types | Thermocouple, RTD, ±mV, 0/4–20mA, 0–10V |
| Control Algorithm | PID auto-tune, On/Off, Ramp & Soak, cascade, ratio, differential |
| Display | 32-character VFD vacuum fluorescent display |
| Operation | 8-button front keypad |
| Communication | RS232, RS485, Modbus RTU |
| Recipe Storage | Up to 8 batch job recipes |
| Output Type | Time proportional digital output, serial DAC analog retransmit |
| Power Supply | 85–264 VAC universal AC input |
| Sampling Rate | 100ms per channel |
| Noise Rejection | 120dB @ 60Hz |
| Temperature Coefficient | 40 ppm/°C |
| Operating Temp | 0°C ~ +55°C |
| Storage Temp | -20°C ~ +70°C |
| Humidity | 5–95% non-condensing |
| Mounting | 1/8 DIN panel mount |
| Enclosure Rating | Front panel IP65, rear IP20 |
| Certifications | CE, UL, C-UL |
| Weight | Approx. 0.75kg |
| Diagnostics | Sensor break, short, overrange, hardware fault |
Compatibility & Installation Pitfalls
Compatibility
- Series: CLS200 family (CLS204 / CLS208 / CLS216)
- Sensors: K, S, B-type thermocouple; Pt100 RTD; 4-20mA / 0-10V transmitters
- Host system: PLC, SCADA via Modbus RTU / RS485
- Output loads: SSR solid state relay, contactor, analog recorder
- Not compatible: CLS100 old generation controllers; single-loop standalone temperature controllers
Critical Installation Pitfalls
- Panel cutout requirement: 1/8 DIN panel cutout, ensure gasket is fitted to maintain front IP65 protection against dust and condensate.
- Analog sensor wiring: Thermocouple must use compensating cable; analog signals use shielded twisted pair, single-point grounding to avoid ground loop drift.
- Ramp-soak recipe backup: Save batch recipes before replacement or firmware update; recipe loss requires re-programming all 16 loops.
- PID tuning sequence: Set sensor scaling first, then auto-tune PID one loop at a time. Multiple loops cross-coupling may cause thermal oscillation.
- Digital output wiring: Time proportional outputs are low-level logic signals, they cannot directly drive high-power heaters; must connect to SSR or contactor.
- Communication bus termination: RS485 Modbus network needs 120Ω terminal resistor at bus two endpoints, otherwise communication error and data loss.
- No hot swap: Controller must be powered down before removal. Live removal will stop all 16 temperature loops and cause process over-temperature risk.
Standard Operating Procedure (SOP)
- Pre-Install Inspection & LOTO Lock-out tag-out AC power and sensor wiring. Inspect front panel, VFD screen and rear terminal block. Confirm model CLS216 CAS200.
- Panel Mounting Insert unit into 1/8 DIN panel cutout, fasten mounting clips, install front sealing gasket.
- Sensor & Output Wiring Wire thermocouple/RTD/compensating cable to input terminals; connect digital outputs to SSR/contactors. Wire RS485 Modbus communication cable. Perform continuity and insulation test.
- Controller Configuration & Recipe Setup Access front keypad or PC configuration software, set sensor type, scale, alarm thresholds, ramp-soak curve, PID parameters. Save batch recipes.
- Power-Up & Commissioning Apply AC power. Verify VFD display and sensor readings. Run static test, then slow thermal cycle test to tune PID and validate alarm functions.
- Runtime Operation & Diagnostics Monitor 16-loop temperature status via front panel or SCADA. Regularly check sensor fault alarms, backup recipes.
- Replacement Procedure Execute LOTO. Disconnect power, sensor and communication cables. Remove old controller. Install spare CLS216, rewire, upload saved recipes, verify all loops.
Application Scenarios
- Industrial furnace & heat treatment multi-zone temperature control
- Plastic extrusion barrel multi-point heating control
- Thermal vacuum oven / environmental chamber batch ramp-soak process
- Semiconductor & packaging thermal processing
- Food and pharmaceutical thermal sterilization
- Refinery / chemical reactor multi-point temperature monitoring
- Retrofit & spare replacement for existing CAS200 / CLS200 thermal control systems
Supporting Components
- 1/8 DIN panel mounting hardware and sealing gasket
- Compensating thermocouple cable / shielded RTD cable
- SSR solid state relays for heater drive
- 120Ω RS485 bus terminating resistor
- Modbus RTU SCADA / PLC host
- PC configuration software for CLS200
- Temperature sensors: Thermocouple, Pt100 RTD
- Circuit breaker for AC power protection
- Terminal blocks and cable glands
- Spare front membrane keypad
Related Model Recommendations (10 Models)
- CLS204: 4-loop version of CLS200 series
- CLS208: 8-loop version of CLS200 series
- CLS216: 16-loop full model
- Watlow F4T: New generation multi-loop controller
- Watlow EZ-ZONE PM: Single loop panel controller
- Watlow SSR solid state relay
- WAGO 758-873 PFC200 PLC (host integration)
- MCS2000-ECA Warner tension controller
- VM600 MPC4 Vibro-Meter vibration card
- IPC704 244-704-000-042-A2-B01-C10 eddy current conditioner