Description
MICROSET 104988-E03 Full English Technical Document
Product Title
MICROSET 104988-E03 Multi-Channel High-Precision Industrial Temperature Control Module

104988-E03
Product Description
The MICROSET 104988-E03 is a compact, high-performance multi-channel industrial temperature control module purpose-built for precise, stable thermal management in diverse industrial automation scenarios. It supports seamless connection with multiple mainstream temperature sensor types, delivers high-resolution synchronous temperature measurement, and integrates closed-loop temperature regulation, multi-channel scanning, and intelligent alarm output functions. Designed for cost-effective, reliable deployment, it features native interoperability with PLCs, solid-state relays, variable speed drives, and HMIs, making it a widely trusted solution for industrial thermal process control that reduces energy consumption and improves overall production efficiency.
Technical Specifications
- Manufacturer: MICROSET
- Part Number: 104988-E03
- Product Type: Multi-Channel Industrial Temperature Control Module
- Supported Input Types: Thermocouples, thermal resistors, and other mainstream industrial temperature sensors
- Core Functions: High-precision temperature measurement, closed-loop temperature regulation, multi-channel synchronous scanning, intelligent alarm output
- Communication Interfaces: USB-C port for firmware upgrade and configuration, standard industrial communication ports for upper system interconnection
- Operating Temperature Range: -10°C to +40°C (for long-term storage), -20°C to +65°C (for normal field operation)
- Safety Compliance: Supports intrinsic safety certification for hazardous industrial zone deployment
- Mean Time Between Failures (MTBF): ≥70000 hours
- Warranty Period: 12 months from factory delivery
Key Features and Advantages
- Multi-channel synchronous sampling architecture enables simultaneous temperature monitoring for multiple measurement points, drastically reducing the number of single-point controllers required for large-scale thermal process scenarios
- Wide compatibility with all mainstream industrial temperature sensor types eliminates the need for additional signal conversion modules, simplifying system integration engineering workload
- High-resolution measurement and closed-loop regulation algorithm ensures ultra-stable temperature control performance, minimizing temperature fluctuation to improve product qualification rate in precision thermal processing
- Native seamless interoperability with PLCs, solid-state relays, variable speed drives, and HMIs supports plug-and-play integration into existing industrial automation systems
- Compact form factor and low power consumption design make it ideal for deployment in space-constrained industrial control panels, reducing total cabinet footprint
- Built-in intelligent alarm function automatically triggers alerts for over-temperature, sensor disconnection, and measurement anomaly conditions, preventing unplanned thermal process failures
- USB-C firmware upgrade interface supports remote function expansion and performance optimization without physical disassembly
- Intrinsic safety certification option enables safe deployment in explosive hazardous industrial environments such as petrochemical plants and oil & gas facilities
Model Parameter Details
| Part Number | Core Configuration |
|---|---|
| 104988-E03 | Standard multi-channel temperature control module, full sensor type compatibility, USB-C configuration port, basic alarm output function, standard industrial communication interface |
Application Fields
- Industrial furnace and heat treatment equipment precise temperature control
- Plastic and rubber processing production line thermal process management
- Food and beverage high-temperature drying and sterilization process temperature monitoring
- Petrochemical plant hazardous area thermal process safety supervision
- New energy lithium battery production line constant temperature environment control
- Pharmaceutical manufacturing GMP-compliant thermal process temperature regulation scenarios
Related Product Recommendations
- MICROSET TMT-Control Official Configuration Software
- MICROSET Industrial Grade K-Type Thermocouple Sensor Set
- MICROSET PT100 High-Precision Thermal Resistor Probe
- MICROSET 104988 Series DIN Rail Mounting Bracket Kit
- MICROSET Intrinsic Safety Barrier Module for Hazardous Areas
- MICROSET Multi-Channel Temperature Data Recording Unit
- MICROSET Solid-State Relay Output Expansion Module
- MICROSET Field Temperature Calibration Toolkit
Pre-Installation Safety Precaution
Before initiating any hardware installation or wiring procedures, ensure all connected industrial thermal processing equipment is fully de-energized, locked out, and tagged in strict compliance with local industrial electrical safety regulations. For deployment in hazardous explosive areas, confirm the module’s intrinsic safety certification fully matches the on-site zone classification requirements before powering on. Only qualified industrial automation and thermal process control personnel with professional operation certification are authorized to perform installation work.
Hardware Installation Steps
- Select a dedicated mounting position on the DIN rail inside the industrial control panel, ensuring sufficient ventilation clearance around the module, avoiding direct exposure to high-temperature radiation, moisture, or corrosive substances
- Secure the module firmly to the DIN rail, confirming the mechanical locking mechanism engages completely to prevent vibration-induced disconnection during long-term operation
- Connect the rated DC 24V auxiliary power wiring to the module’s dedicated power terminals, verifying the power supply voltage matches the module’s rated specification before applying power
- Terminate all temperature sensor field wiring strictly following the official MICROSET wiring schematic, confirming signal polarity and terminal labeling accuracy
- Wire all alarm output and upper system communication cabling with proper shielding grounding, to eliminate electromagnetic interference impact on signal transmission stability
- Torque all wiring terminals to the specified torque values, and install dedicated cable strain relief for all external field wiring runs
System Configuration Workflow
- Power on the module after completing all wiring checks, confirm the power indicator LED on the front panel illuminates in normal steady state
- Connect the configuration workstation to the module’s USB-C port, launch the official MICROSET TMT-Control software to establish stable point-to-point communication
- Complete basic device parameter setup, including site identification, local time synchronization, and each channel’s corresponding sensor type configuration
- Set all temperature control parameters, including target temperature setpoints, control loop gain, and over-temperature alarm thresholds
- Configure communication protocol parameters, enabling seamless data exchange with the upper-level PLC or HMI system
- Customize multi-channel scanning sequence and alarm output logic according to specific on-site thermal process requirements, then save the full configuration profile to non-volatile onboard memory
Post-Installation Verification Checklist
- Confirm all front-panel status LEDs operate in normal state, with no persistent active fault or warning indicators
- Validate that real-time measured temperature values for all channels fully match the reference temperature of field calibration sources
- Perform closed-loop temperature regulation testing, confirming the module maintains stable temperature control within the specified fluctuation range
- Test the sensor disconnection and over-temperature alarm functions manually, confirming the module triggers corresponding alarm outputs as designed
- Verify end-to-end communication connectivity between the module and the upper-level industrial automation system, confirming complete, uncorrupted temperature data transmission
- Trigger the built-in self-diagnostic routine manually, confirming all hardware channel health monitoring and fault detection functions operate correctly