CC-PAIH01 is Series C high-level analog input module with native HART support for Honeywell Experion PKS C300/C200 controller. It acquires 4–20mA signals from field HART transmitters (pressure, flow, temperature, level). Besides analog measurement, the integrated HART modem reads multi-variable data, device tag, calibration status, sensor diagnostics from smart transmitters over same 4–20mA wiring. This IOM plugs onto dedicated IOTA termination assembly for field wiring. It is legacy Series C hardware; upgraded drop-in replacement is CC-PAIH51. Honeywell no longer manufactures new production units, only surplus / refurbished spares available for existing DCS plants.

CC-PAIH01

Key Technical Specifications

  • Part Number: CC-PAIH01, 51405038-175
  • Manufacturer: Honeywell
  • Platform: Experion PKS Series C I/O Module, works with C300 / C200 controller via IOLINK
  • Channels: 8 high-level analog input channels, HART 5/7 compatible
  • Input Signal: 4–20mA from 2-wire HART transmitters
  • ADC Resolution: 16-bit
  • Accuracy: ±0.08% FS typical @25℃
  • Channel Isolation: Channel-to-backplane isolation ≥2500VAC
  • Diagnostics: Wire break detection, over-range / under-range, transmitter fault, HART device status
  • Matching IOTA terminal assemblies:
    • Non-redundant: CC-TAIH01
    • Redundant IOTA: CC-TAIH11
  • Communication: IOLINK bus to C300 controller
  • Power: Powered by Series C rack backplane
  • Operating Temperature: 0 ~ +60°C
  • Storage Temperature: -40 ~ +85°C
  • Humidity: 5~95% non-condensing
  • Hazardous approval: Class I Div 2 non-incendive
  • Weight: ~0.40 kg

CC-PAIH01

Recommended 8 Similar Series C I/O Models

  1. CC-PAIH51 (Revised upgraded HART AI, drop-in replacement for CC-PAIH01)
  2. CC-PAIX01 (16CH Non-HART analog input)
  3. CC-PAOH01 (16CH HART Analog Output, previous item)
  4. CC-PAOX01 (16CH AO without HART)
  5. CC-PDIS01 Digital Input Series C
  6. CC-PDOX01 Digital Output
  7. CC-TAIH01 IOTA terminal base for CC-PAIH01
  8. CC-CF01 C300 Controller

 

Quality Control & Test Standard Operating Procedure (SOP)

  1. Visual Inspection: Inspect PCB, front panel LED, gold edge fingers, connector and label, confirm PN CC-PAIH01 / 51405038-175, check corrosion, burnt marks or bent pins.
  2. Continuity Test: Check backplane edge pins, power and signal traces for open/short circuit.
  3. Insulation Resistance Test: Insulation test between backplane power and each AI input channel.
  4. Power-Up Functional Test: Mount module on matching IOTA in Series C rack, apply rack power, verify LED boot status, no overheating.
  5. ADC Calibration Test: Inject precision 4–20mA signal to each channel, verify reading accuracy and linearity.
  6. HART Communication Test: Connect HART transmitter simulator, validate polling, tag reading, multi-variable & diagnostic retrieval.
  7. Wire-break & out-of-range simulation: Simulate open field wire, under/over range to trigger channel fault alarms.
  8. IOLINK Bus Communication Test: Connect to C300 controller, verify measurement upload and diagnostic status exchange.
  9. Environmental Burn-in Test: Powered burn-in at rated temperature for early failure screening.
  10. Final Recheck & Documentation: Repeat analog input and HART test, generate serial-number traceable test report before anti-static packaging.

 

New Module Installation Guide

  1. Pre-Install Preparation: Execute LOTO lockout-tagout for DCS cabinet. Wear ESD wrist strap. Confirm CC- compatible with C300 firmware and paired IOTA (CC-TAIH01 / CC-TAIH11).
  2. Rack & IOTA Inspection: Inspect Series C rack backplane and IOTA base connectors for oxidation or damage.
  3. Module Insertion: Plug CC- onto IOTA termination base and lock latch.
  4. Field Wiring: Wire 2-wire HART transmitters to IOTA terminals, use shielded twisted pair, follow Honeywell grounding specification.
  5. Power Restore: Energize rack 24VDC power, observe module LED initialization and IOLINK link.
  6. Commissioning: Open Experion PKS engineering station, configure channel ranges, enable HART polling, assign tag parameters.
  7. Loop Test: Inject mA signals for each channel, verify DCS readings and HART device diagnostic information.
  8. Post-Installation Documentation: Record serial number, channel configuration, HART instrument list and commissioning log in plant asset record.

 

Application Scenarios & Features

Application Scenarios

  • Honeywell Experion PKS DCS in refinery, petrochemical, natural gas process plants
  • Thermal power plant boiler process measurement (pressure, flow, temperature, liquid level)
  • Collect 4–20mA + HART diagnostics from smart field transmitters
  • Spare replacement for failed HART AI IOM in existing Series C racks

Core Features

  • 8-channel high-level analog input with built-in HART modem for smart transmitters
  • 16-bit high precision ADC, excellent measurement accuracy for process variables
  • Simultaneously read analog value and HART device health / multi-variable data on same loop
  • Built-in per-channel diagnostics: open wire, out-of-range, transmitter fault detection
  • Works with dedicated IOTA terminal assembly, redundant IOTA option available
  • Hot-swappable plug-in Series C IOM for Experion PKS controller
  • Suitable for Class I Div 2 hazardous process areas

 

FAQ

Q1: What is difference CC- vs CC-PAIH51?

A1: CC- is original older version; CC-PAIH51 is upgraded revision, drop-in compatible with same IOTA, improved component reliability.

Q2: What is IOTA?

A2: IOTA = Input Output Termination Assembly, the wiring base. The IOM module plugs onto IOTA; field cables land on IOTA terminals. CC- needs CC-TAIH01 (non-redundant) / CC-TAIH11 (redundant).

Q3: Can CC- hot swap?

A3: Mechanically hot plug supported. If channels are live process measurements, removing module will lose readings; replace only during maintenance shutdown window.

Q4: Is CC- SIL certified?

A4: It is basic process control I/O, not SIL safety rated. SIL applications use Honeywell Safety Manager SIS hardware.

Q5: Common failures of CC-?

A5: ADC drift, HART modem failure, gold finger oxidation, input circuit damage from field overvoltage, IOTA terminal corrosion.

Q6: Is CC- discontinued?

A6: Yes, Honeywell ceased new production; only surplus new or refurbished spare stock available for existing Experion PKS plants.

Q7: CC- vs CC-PAOH01?

A7: CC-: HART Analog Input (reads field transmitters). CC-PAOH01: HART Analog Output (sends signal to valves/positioners).

Q8: What controller does CC- connect to?

A8: Honeywell / C200 Experion PKS controller via IOLINK bus.