Description
GE Multilin 369-HI-R-M-0-0-0-E Digital Motor Management & Protection Relay
Executive Summary
The GE Multilin 369-HI-R-M-0-0-0-E is a high-performance digital motor management relay developed by GE Multilin, designed for comprehensive protection, metering, monitoring and fault recording of three-phase industrial motors. This specific model is configured with HI high-range control power, 12-channel RTD temperature input and enhanced metering package. It supports adaptive motor thermal modelling, 15 standard protection curves plus user-defined FlexCurve™. Equipped with multi-port serial communication, 512-event recorder and oscillography waveform capture, it can be connected to SCADA and EnerVista configuration software for remote monitoring and parameter setup. Widely deployed for critical pumps, fans, compressors and conveyors in oil & gas, chemical, water treatment, power and mining industries to prevent motor burnout and reduce unplanned downtime.
Core Technical Specifications
- Manufacturer: GE Multilin (General Electric, Origin: Canada)
- Model: 369-HI-R-M-0-0-0-E
- Control Power (HI): 60–265 VAC / 50–300 VDC, 50/60Hz
- Current Input: 1A or 5A secondary, software selectable
- RTD Input (Option R): 12 channels, support Pt100, Ni120 and other RTD sensors
- Metering Package (Option M): Voltage, frequency, kW, kVAR, power factor & energy metering
- Relay Output: 4 programmable Form-C contact outputs
- Communication: 1 × front RS232; 3 × rear RS485, Modbus RTU protocol
- Protection Curves: 15 standard overload curves + FlexCurve™ custom curve
- Data Recording: 512 event logs + oscillography waveform capture
- Operating Temperature: -40℃ ~ +60℃
- Storage Temperature: -40℃ ~ +85℃
- Relative Humidity: 5% ~95%, non-condensing
- Protection Class: IP50 (front panel)
- Weight: Approx. 3.4kg
- Mounting: Panel mount
Main Features & Advantages
- Full-suite motor protection functions: Overload, locked rotor / stall, ground fault, phase loss, unbalance, over/under voltage protection to cover common motor failure modes.
- Adaptive thermal model: The relay automatically learns motor acceleration time, inrush and cooling characteristics for precise thermal protection.
- 12-channel RTD temperature monitoring: Real-time stator and bearing temperature measurement for early overheat pre-alarm.
- Enhanced electrical metering: Measure power, energy, power factor and frequency for energy audit and load analysis.
- Rich data recording: Event log and oscillography capture fault waveforms to accelerate root cause analysis after trip events.
- Multi-port serial communication: Front RS232 for local configuration; rear RS485 for connection to SCADA/HMI via Modbus RTU.
- User-customizable FlexCurve™: Custom overload curve for special motors that do not fit standard IEC/ANSI curves.
- Robust industrial hardware: Wide range universal control power, withstand harsh industrial environments, proven reliability for critical motor assets.
Application Scenarios
- Oil & gas pump and compressor motor protection
- Chemical plant critical fan, agitator and conveyor motors
- Power plant auxiliary motor protection (boiler fans, circulating water pumps)
- Water & wastewater treatment large pump stations
- Mining and cement heavy-duty conveyor motors
- Pulp & paper process motor monitoring
- HVAC large motor systems for industrial buildings
Recommended Related Models (8pcs)
- GE Multilin 369-HI-R-0-0-0-E Motor Relay
- GE Multilin 369-LO-R-M-0-0-0-E Low Power Version
- GE Multilin 369-HI-R-M-F-0-E With Fiber Port
- GE Multilin 345 Feeder Protection Relay
- GE Multilin 469 Motor Management Relay
- GE Multilin 745 Transformer Protection Relay
- GE Multilin 489 Generator Management Relay
- GE Multilin 350 Feeder Protection Relay
FAQ
Q1: What does the model code 369-HI-R-M-0-0-0-E stand for? A: HI = High range control power; R = 12 RTD inputs; M = Enhanced metering package; E = Enhanced firmware feature set.
Q2: Is 369-HI-R-M-0-0-0-E still in production? A: This 369 series relay is end-of-manufacture. Available supply is original surplus new spare stock for plant maintenance replacement.
Q3: What software is used to configure this relay? A: GE EnerVista 369 Setup software, connect via front RS232 port to upload/download settings and view fault records.
Q4: What RTD types does the R option support? A: Pt100 platinum, Ni120 nickel and other standard RTD types, selectable via software.
Q5: Can it be used for medium voltage motors? A: Yes, it is widely applied on MV motors, working with external current and voltage transformers.
Q6: What communication protocol does it use? A: Standard Modbus RTU over RS485 for SCADA integration.
Q7: How many fault events can it store? A: Up to 512 event records plus oscillography waveform capture for post-fault analysis.
Q8: What is the difference between GE 369 and 469 relay? A: 369 is designed for smaller to medium industrial motors; 469 is higher-end model for large critical motors with extra protection options.