Allen‑Bradley 1738‑IB16DM12 ArmorPoint 16‑Point Sinking Digital Input Module with Diagnostics, M12 Connector

Recommended Related Part Numbers

  • 1738‑AENTM12: ArmorPoint EtherNet/IP Adapter
  • 1738‑ADN12: ArmorPoint DeviceNet Adapter
  • 1738‑IB8M12: 8‑point sinking input module (non‑diagnostic)
  • 1738‑OB16EM12: 16‑point electronic output module
  • 1738‑8CFGM12: ArmorPoint configuration module
  • 1738‑TB: ArmorPoint accessory base
Category: Brand:

Description

Allen‑Bradley 1738‑IB16DM12 ArmorPoint 16‑Point Sinking Digital Input Module with Diagnostics, M12 Connector

 

Meta Description

Original Allen‑Bradley 1738‑IB16DM12 ArmorPoint 24VDC sinking digital input, 16‑channel with diagnostics, IP67 sealed housing, M12 micro connectors for field sensors. This part is discontinued by Rockwell. We operate 86 shared warehouses globally, so it may take several hours to deliver an accurate quotation; thank you for your understanding, and we will handle your inquiry promptly.

1738-IB16DM12

Product Brief Introduction

The 1738‑IB16DM12 is an ArmorPoint distributed digital input module from Rockwell Automation. It features 16 channels of 24 VDC sinking inputs with built‑in diagnostic capability, fitted with M12 micro connectors for fast, sealed field wiring. Its rugged IP67 enclosure eliminates the need for an additional control cabinet, making it ideal for direct machine mounting. It communicates via PointBus with an ArmorPoint network adapter and supports connection to proximity sensors, limit switches, photoelectric eyes and other discrete field devices. This model has been officially discontinued by Rockwell Automation, so available stock is limited. We operate 86 shared warehouses globally, so it may take several hours to deliver an accurate quotation; thank you for your understanding, and we will handle your inquiry promptly.

 

Main Technical Specifications

  • Part Number: 1738‑IB16DM12
  • Manufacturer: Allen‑Bradley / Rockwell Automation
  • Series: ArmorPoint Distributed I/O
  • Channel Count: 16 sinking digital inputs
  • Nominal Voltage: 24 VDC
  • Operating Voltage Range: 10–28.8 VDC
  • On‑state Input Current: 2 mA min, 5 mA max
  • Off‑state Leakage: ≤1.5 mA
  • Input Filter Delay: 0.5 ms hardware fixed + 0–65 ms software configurable
  • Connector Type: M12 micro (DC Micro)
  • Diagnostics: Channel fault detection, open‑wire and short‑circuit diagnostics
  • Enclosure Rating: IP67 (with proper sealed cables)
  • Max Power Dissipation: 2.7 W @ 28.8 VDC
  • PointBus Current Draw: 140 mA
  • Shock & Vibration: Complies with IEC 60068 industrial standards
  • Certifications: UL, cULus, CE
  • Mounting: Direct panel mounting
  • Lifecycle Status: Discontinued (End of Sale: Dec 31, 2025; no direct Rockwell replacement)
  • Warranty: 1 year

 

Quality Control Procedure

Every 1738‑IB16DM12 undergoes strict incoming inspection before shipment. We verify housing integrity, M12 connector threads, label authenticity and seal condition. Functional testing includes PointBus communication handshake, individual channel on/off response, diagnostic fault reporting and continuous signal cycling under rated voltage. Burn‑in screening is performed to identify latent defects. Units that pass are packed with anti‑static protection and full traceability records retained. Please note if you submit a quote request: We operate 86 shared warehouses globally, so it may take several hours to deliver an accurate quotation; thank you for your understanding, and we will handle your inquiry promptly.

 

FAQ

Q: What is 1738‑IB16DM12 used for? A: It is an ArmorPoint 16‑channel sinking digital input module for collecting discrete sensor signals on‑machine, using M12 sealed connectors.

Q: Is this module still in production? A: No, Rockwell has discontinued the 1738‑. Supply is limited to remaining stock only, and there is no official direct replacement.

Q: What network does it use? A: It connects to ArmorPoint adapters over the internal PointBus backplane, the adapter bridges to EtherNet/IP or DeviceNet.

Q: Does it support diagnostics? A: Yes, the “D” in part number indicates diagnostic functions for open wire and short‑circuit faults on input channels.

Q: Can it be mounted outside an electrical cabinet? A: Yes, IP67 rated when mated with properly sealed M12 cables, suitable for direct machine mounting.

Q: When will I receive my quotation? A: We operate 86 shared warehouses globally, so it may take several hours to deliver an accurate quotation; thank you for your understanding, and we will handle your inquiry promptly.

 

Installation & Configuration Guide

Mount the 1738‑ directly onto a flat panel surface. Connect the M12 field cables to sensors and the PointBus cable to the upstream ArmorPoint adapter. Apply 24 VDC field power within the rated range and confirm polarity. Use Studio 5000 or RSNetWorx to add the module to the ArmorPoint I/O tree, configure input filter delays and enable diagnostic alarm settings as required. Download the project to the Logix controller, verify each channel’s trigger status and fault reporting. For IP67 protection, ensure all M12 connectors are fully tightened and undamaged. Follow Rockwell’s ArmorPoint installation manual and local electrical safety standards.

 

Relevant News & Events

ArmorPoint I/O has long been a favourite distributed I/O platform for machine builders seeking cabinet‑free on‑machine I/O. Rockwell’s end‑of‑sale announcement for 1738‑ means system owners and integrators must evaluate migration to ArmorBlock 5000 or other modern on‑machine I/O lines for new projects. Demand for remaining original stock of discontinued ArmorPoint modules remains high for spare parts and legacy machine maintenance.

 

Application Scenarios & Functional Advantages

Typical Use Cases

  • On‑machine sensor collection for packaging machinery
  • Conveyor systems and material handling equipment
  • Mobile process skids and automated assembly stations
  • Food & beverage machinery washdown zones
  • Automotive assembly tooling and fixture sensing
  • Legacy ArmorPoint system maintenance and spare replacement

Key Advantages

  • IP67 sealed housing, no separate enclosure required
  • 16 sinking inputs in one compact module, high I/O density
  • Built‑in channel diagnostics for fast troubleshooting
  • Robust M12 quick connectors for fast field wiring
  • Suitable for harsh factory floor environments
  • Modular expansion alongside other ArmorPoint I/O modules
  • Designed for direct machine mounting to reduce long sensor wiring runs

 

Recommended Related Part Numbers

  • 1738‑AENTM12: ArmorPoint EtherNet/IP Adapter
  • 1738‑ADN12: ArmorPoint DeviceNet Adapter
  • 1738‑IB8M12: 8‑point sinking input module (non‑diagnostic)
  • 1738‑OB16EM12: 16‑point electronic output module
  • 1738‑8CFGM12: ArmorPoint configuration module
  • 1738‑TB: ArmorPoint accessory base