1492-IFM40F — Allen-Bradley (Rockwell Automation) 40-Point Feed-Through Digital Interface Module (1492 I/O Wiring System)

Related Product Recommendations

Model Description
Fusible variants of the same 40-point IFM — 5×20 mm fuse clips, blown-fuse LED indication, 4 terminals per point
1492-CABLE series Prewired cables (40-pin connector to PLC-module interface) — select via ClearTools cable matrix
1492-IFM16F / 1492-IFM32F Other point-count feed-through/fused digital IFMs in the 1492 family
1492-AIFM series Analog interface modules for analog I/O breakout
1756 digital I/O modules / 5069 CompactLogix Typical controller I/O cards interfaced through this wiring system
1492-TD008 / 1492-TD019 / 1492-UM001 Official technical data and user manual publications for pinout and ratings
Category: Brand:

Description

1492-IFM40F — Allen-Bradley (Rockwell Automation) 40-Point Feed-Through Digital Interface Module (1492 I/O Wiring System)

1492-IFM40F

Brand & Model Title

Allen-Bradley 1492-IFM40F — Bulletin 1492 Programmable Controller Wiring System, 40-Point Feed-Through Digital Interface Module (IFM), Standard Type, Fixed Screw Terminal Block

The 1492-IFM40F is a passive, high-density digital interface module of the Rockwell Automation 1492 wiring system: it converts a 40-pin high-density cable connector into 40 individually labeled screw terminals, replacing tedious point-to-point panel wiring between PLC digital I/O modules (16- and 32-point ControlLogix/PLC platforms) and field devices via prewired 1492-CABLE trunk cables. The base 1492-IFM40F is the non-fused, standard feed-through version — the fused siblings carry the -FS/-F24 ordering suffixes (e.g., 1492-IFM40F-FS120-4 with 5×20 mm fuse clips and blown-fuse LED indication). Lifecycle status: Active in the current Rockwell catalog.

 

Main Technical Specifications

Parameter Value
Product type 40-point feed-through digital interface module (passive wiring termination)
Family Bulletin 1492 Programmable Controller Wiring Systems (1492-Connection devices)
Interface style Feed-through; one field-side terminal per I/O connection
Field-side terminals 40 screw terminals (fixed terminal block)
Cable connector 40-pin female connector for prewired cables; interfaces digital I/O from 16 to 32 points
Voltage rating 0–132 V AC/DC maximum
Current rating 2 A maximum per circuit; 12 A maximum per module
Recurring peak voltage 600 Vp (transients above 600 Vp require 2.5 kV suppression)
Wire size 22–12 AWG (0.5–2.5 mm²)
Mounting Standard 35 mm DIN rail
Dimensions ~110 (W) × 83 (H) × 70.5 mm (D)
Weight ~0.28–0.39 kg (listings vary by packaging basis)
Environment Operation 0…60 °C; humidity 5–95% non-condensing
Certifications cULus Listed, CE, FM Class I Division 2
UPC / origin 662468170215; Country of origin: Mexico
Related publications 1492-TD008 / 1492-TD019 (technical data), 1492-UM001 (user manual), 1492-TD018 (CompactLogix wiring)
Keyed variants -FS24-2 / -FS120-4 / -FS120A-4 — isolated fusible versions with 5×20 mm fuse clips, 24/120 V AC/DC ratings, blown-fuse LED indicators, and 4 terminals per point

 

Typical Applications

  • PLC I/O wiring termination — breakout of 16- and 32-point Allen-Bradley digital I/O cards (ControlLogix 1756, SLC/PLC-5 legacy platforms) to screw terminals via prewired 1492-CABLE assemblies
  • Panel wiring standardization — reducing point-to-point hand wiring, wiring errors and commissioning time in new control cabinets and machine retrofits
  • Troubleshooting and test points — clean external terminals for measuring field circuits without touching the PLC connector
  • Connector wear protection — shielding the PLC’s I/O connector from repeated field-cable plug/unplug cycles during maintenance
  • Upgrade path to fused protection — when per-point fusing is later required, the fusible -FS/-F24 variants of the same footprint provide integrated 5×20 mm fuse holders without rewiring the cabinet

 

Related News & Events

  • Active product lifecycle:​ Rockwell Automation lists 1492-IFM40F as Active (standard lead time ~5 days, 1-year warranty) — this is a current production item, not an obsolete spare; EU/Eurasian certifications were re-confirmed on 2026-08-11 per the official product page.
  • Fusible family expansion:​ the -FS120-4 / -FS120A-4 variants (isolated fusible, 5×20 mm clips, 120 V AC/DC, blown-fuse indication, 4 terminals per point) remain Active as well, and Rockwell’s wiring documentation (1492-TD018/TD008) now positions the 1492 IFM range for both legacy ControlLogix and newer 5069 CompactLogix wiring systems.
  • ClearTools software ecosystem:​ the 1492 wiring system is supported by Rockwell’s ClearTools (v4.5 through v9.4) for automated cable/fused-interface selection, label generation and cabinet documentation — the official selection path when specifying prewired cables and IFMs.
  • Market caution — fabricated listings:​ this part number attracts AI-generated “spec sheets” describing it as an “intelligent power distribution monitoring module” (40-feeder current/voltage metering, EtherNet/IP, arc detection, 1000-event logs) or a “Genius 40-point fused module.” None of these are real — the authoritative Rockwell classification is a passive 40-point feed-through digital IFM with no electronics, no communication, and no measurement functions.