Description
140XCP51000 — Schneider Electric Modicon Quantum Dummy Module with Cover (for Discrete I/O Module Position)

Brand & Model Title
Schneider Electric 140XCP51000 — Modicon Quantum Dummy Module with Cover, for Discrete I/O Module Slots
The 140XCP51000 is a passive mechanical accessory, not a functional I/O or communication module. It fills unused slots in a Modicon Quantum rack at discrete I/O module positions, with an integrated hinged front cover. It protects the exposed backplane, blocks dust and debris, prevents accidental contact, and keeps the rack front visually complete when slots are reserved for future expansion or left vacant after module removal.
Main Technical Specifications
| Parameter | Value |
|---|---|
| Product type | Dummy module (slot filler) with cover |
| Platform | Modicon Quantum automation platform |
| Destination | Quantum discrete I/O module slot positions |
| Function | Occupies unused slots; protects backplane and slot interior; covered front panel (hinged, swings fully open for later module insertion) |
| Active electronics | None — purely mechanical; no field signals, no I/O addressing, no software configuration |
| Construction | Flame-retardant molded housing (typical UL94 V-0 thermoplastic); cover flush with neighboring module faces |
| Protection | IP20 (installed, indoor control cabinet use) |
| Environment (typical) | Operation 0…60 °C; storage −40…85 °C; up to 95% RH non-condensing |
| Unit weight | ~0.31–0.33 kg; package 31.0 × 16.4 × 4.6 cm |
| GTIN | 3595861135284 |
| Country of origin | France |
| Related reference | 140XCP50000 — the dummy-module execution without cover/terminal block; 140XCP51000 is the covered version |
Typical Applications
- Vacant-slot protection — covering unused slots in main, remote and expansion racks to keep dust, moisture and foreign objects off the backplane connectors
- Reserved-slot management — cleanly marking slots kept for future I/O, communication or special-function module additions
- Brownfield maintenance — filling positions after a module is removed for testing, replacement or troubleshooting, without leaving open cavities
- Cabinet tidiness and inspection compliance — maintaining an approved rack-population layout and a covered front face for cabinet audits
- All Quantum architectures — valid in local, remote (S908 RIO), distributed and hot-standby racks; no CPU restrictions
Related News & Events
- Lifecycle: this reference sits in the Quantum accessory family, which Schneider Electric has been phasing out alongside the platform. No official stop-of-sale/end-of-service dates were confirmed on the public se.com page at the time of writing — verify the current lifecycle banner (many regional pages show “limited sales service” status for Quantum accessories) before ordering.
- Quantum platform sunset: as part of the broader Quantum-to-M580/X80 transition (140-series references discontinued between 2018 and 2026, service ending 2026–2030), dummy modules are now primarily procured as maintenance spares for installed bases.
- Caution on third-party data: this part number is heavily mis-listed in the spare-parts market — distributor pages variously describe it as a Modbus Plus coprocessor, an RIO station adapter, an inter-rack cable, or even a servo drive. These are AI-generated or mismatched listings. The authoritative se.com classification is “dummy module with cover — for discrete I/O module.”
- Installation notes: isolate rack power before inserting or removing; never assign field channels or controller I/O words to a dummy-module position; verify full seating and cover closure, and keep the as-built rack drawing aligned with the reserved positions.


