Description
Triconex 8111 Tricon Chassis Redundant Power Supply Module
Executive Summary
The Triconex 8111 is a classic rack-mounted redundant power supply unit developed by Triconex (Schneider Electric) for Tricon TMR Safety Instrumented System (SIS). It converts universal AC input into regulated DC power for the Tricon backplane, feeding main processor boards, analog/digital I/O modules and communication cards. It supports 1+1 parallel redundant load-sharing configuration; if one power supply fails, the backup unit seamlessly takes over the full load without interrupting safety control logic. The module continuously monitors internal voltage, current and temperature via built-in diagnostic circuits. Front panel PASS and FAULT LEDs offer direct visual status indication, while dry relay contacts provide remote fault alarm signals. Widely used in oil & gas, petrochemical, power generation and chemical ESD emergency shutdown systems, it serves as a core spare unit for maintenance and retrofitting of legacy Tricon safety cabinets.
Core Technical Specifications
- Manufacturer: Triconex (Schneider Electric, USA)
- Model: 8111
- Product Type: Tricon Chassis Redundant Power Supply Module
- Input Voltage: 85–264 VAC, 47–63Hz
- Rated Power: 175W @ 60℃ ambient
- DC Output: +5VDC logic power and auxiliary 24VDC for backplane
- Redundancy Mode: 1+1 parallel load sharing
- Protection Functions: Overvoltage(OVP), Overcurrent(OCP), Short-circuit protection, Over-temperature protection
- Alarm Output: Dry contact relay for remote fault alarm
- Cooling: Built-in fixed cooling fan
- Safety Compliance: IEC61508 SIL3 compatible for safety instrumented system
- Operating Temperature: 0℃ ~ +60℃
- Storage Temperature: -40℃ ~ +85℃
- Relative Humidity: 5% ~95%, non-condensing
- Status LED: PASS, FAULT
- Mounting: Slide-in power module for Tricon main/expansion chassis
- Net Weight: Approx.2.5 kg
- Origin: United States
Main Features & Advantages
- Dual redundant power design: Two 8111 modules operate in parallel load sharing. Single unit failure will not cause SIS system shutdown.
- Wide universal AC input range: 85~264VAC input adapts to different industrial power grids globally.
- Stable dual DC power rails: Supplies +5V logic power and auxiliary 24V power to all TMR boards on the backplane.
- Complete hardware protection suite: OVP, OCP, short-circuit and over-temperature shutdown to protect expensive Tricon controller and I/O cards.
- Integrated hardware self-diagnosis: Real-time monitoring of input loss, output drift and over-temperature, with relay alarm for remote notification.
- Hot-swap support: Online replacement is available while the Tricon system keeps running to reduce plant downtime.
- SIL3 safety compatibility: Designed for safety-critical SIS/ESD loops and meets IEC61508 functional safety requirements.
- Standard Tricon rack form factor: Plug-and-play installation, compatible with legacy Tricon main and expansion chassis.
Application Scenarios
- Petrochemical refinery ESD emergency shutdown cabinets
- Offshore platforms and natural gas pipeline safety control systems
- Thermal power plant boiler and turbine safety interlock protection
- Hazardous chemical process safety instrumented systems
- Tank farm high-risk area safety control cabinets
- Legacy Tricon TMR system power overhaul and spare backup
- Safety interlock system for fertilizer and fine chemical plants
Recommended Related Models (8pcs)
- 8117 Upgraded Tricon Redundant Power Supply
- 8110 Tricon Main Chassis
- 3006 Tricon Main Processor Module
- 3721 32-channel Analog Input Module
- 3503E Digital Input Module
- 3625 Digital Output Module
- 4351B TCM Communication Module
- 3805E Analog Output Module
FAQ
Q1: What is Triconex 8111? A: Triconex 8111 is the classic redundant rack power supply for Tricon SIL3 safety instrument system, providing backplane DC power for CPU, I/O and communication modules.
Q2: What is the difference between 8111 and 8117? A: 8111 is the original legacy power supply; 8117 is the updated version with enhanced fan fault detection and improved thermal protection. They share the same rack form factor.
Q3: Is Triconex 8111 still in production? A: The classic Tricon series including 8111 has been discontinued by Schneider Triconex. Available stock includes original new surplus and fully tested refurbished units.
Q4: Can 8111 work in redundant configuration? A: Yes. Two 8111 modules are installed in one chassis for 1+1 load-sharing redundancy. The remaining unit can fully support the entire chassis load after one fails.
Q5: Does it support hot swap? A: Hot swap is supported. On-site replacement must strictly comply with LOTO lockout-tagout and safety work permit procedures.
Q6: What conditions trigger the fault relay alarm? A: AC input loss, output overvoltage/undervoltage, over-temperature and internal hardware failure will activate the dry contact alarm.
Q7: What is the rated power of 8111? A: Rated 175W at 60℃ ambient temperature, sufficient to power a fully populated Tricon chassis.
Q8: What are common faults of 8111? A: Cooling fan wear and stall, electrolytic capacitor degradation, output voltage drift, backplane connector oxidation and intermittent FAULT alarm.