The ABB PFTL101A 1.0KN (official part number 3BSE004166R1) is a high-precision horizontal tension load cell belonging to the ABB industrial force measurement product family

  1. PFTL101A 0.5KN (3BSE004160R1): 0.5kN lower range tension load cell, for light material low-tension production line applications
  2. PFTL101A 2.0KN (3BSE004172R1): 2.0kN higher range tension load cell, for heavy material high-tension production line applications
  3. PFEA111: ABB Tension Controller, the dedicated signal processing unit paired with this PFTL101A series load cell
  4. PFTL201A: ABB High-Capacity Tension Load Cell, for ultra-heavy web high-tension industrial applications
  5. AC 800M: ABB Distributed Control System, the native host control platform for integrating tension measurement data into full production line automation
  6. CI871K01 3BSE056767R: ABB PROFINET IO Communication Interface Module, enabling high-speed tension data transmission to upper-level control systems
  7. CP451-51: ABB Centum VP Processor Module, for large-scale continuous production line distributed control system deployment
  8. PFTL101B: ABB Upgraded Generation Tension Load Cell, fully backward compatible with the PFTL101A series for system modernization
Category: SKU: THE ABB PFTL101A 10KN Brand:

Description

Product Core Overview

The ABB PFTL101A 1.0KN (official part number 3BSE004166R1) is a high-precision horizontal tension load cell belonging to the ABB industrial force measurement product family. Purpose-built for continuous web production line tension monitoring and control, it delivers accurate, stable force measurement up to 1.0 kilonewton, making it a mission-critical component widely deployed in papermaking, printing, packaging, metal processing and other continuous material production industries worldwide. Manufactured in Sweden, it features solid stainless steel construction and IP66/IP67 ingress protection, delivering long-term reliable operation in harsh industrial environments with high humidity, dust and water spray conditions .

 

Key Technical Specifications

  • Official Part Number: PFTL101A 1.0KN
  • Full Order Code: 3BSE004166R1
  • Manufacturer: ABB
  • Product Type: Horizontal Tension Load Cell
  • Rated Measuring Range: 0–1.0 kN (1000 Newtons)
  • Measurement Accuracy: ±0.1% of full scale
  • Response Time: <10ms ultra-fast dynamic response
  • Output Signal: Standard industrial tension measurement analog signal, fully compatible with ABB PFEA series tension controllers
  • Power Supply: 24V DC (18–36V wide operating voltage range)
  • Operating Environment: 0°C to +55°C operating temperature, 5%–95% non-condensing relative humidity
  • Mechanical Construction: Solid stainless steel one-piece body, no moving parts for zero maintenance long service life
  • Ingress Protection: IP66 / IP67, fully dust-proof and resistant to low-pressure water jet cleaning
  • Net Weight: Approximately 2kg
  • Safety Certification: EU CE industrial safety certified

PFTL101A 1.0KN

8 Recommended Related Series Models

  1. PFTL101A 0.5KN (3BSE004160R1): 0.5kN lower range tension load cell, for light material low-tension production line applications
  2. PFTL101A 2.0KN (3BSE004172R1): 2.0kN higher range tension load cell, for heavy material high-tension production line applications
  3. PFEA111: ABB Tension Controller, the dedicated signal processing unit paired with this PFTL101A series load cell
  4. PFTL201A: ABB High-Capacity Tension Load Cell, for ultra-heavy web high-tension industrial applications
  5. AC 800M: ABB Distributed Control System, the native host control platform for integrating tension measurement data into full production line automation
  6. CI871K01 3BSE056767R: ABB PROFINET IO Communication Interface Module, enabling high-speed tension data transmission to upper-level control systems
  7. CP451-51: ABB Centum VP Processor Module, for large-scale continuous production line distributed control system deployment
  8. PFTL101B: ABB Upgraded Generation Tension Load Cell, fully backward compatible with the PFTL101A series for system modernization

 

Professional Quality Control Test Standard Operating Procedure

  1. Pre-Test Visual Audit: Inspect the stainless steel body for physical deformation, corroded signal cable terminals or loose components; confirm no mechanical damage or surface crack exists on the load cell force sensing area
  2. Zero Point Calibration Validation: Mount the load cell on a certified test fixture, confirm the zero point output deviation stays within ±0.05% of full scale under no-load condition
  3. Full Range Performance Test: Apply certified standard weights across 0% to 100% of 1.0kN rated range, confirm every measurement point accuracy stays within ±0.1% of full scale
  4. Overload Protection Validation: Apply 150% of 1.0kN rated overload force, confirm no permanent mechanical deformation or measurement drift occurs after load removal
  5. Environmental Humidity Cycling: Place the module in a constant temperature and humidity chamber, run 48-hour 95% relative humidity test, confirm no signal drift or performance degradation
  6. Vibration Resistance Test: Simulate industrial production line 10–2000Hz vibration environment, confirm no loose internal components or unstable signal output occurs
  7. IP Protection Validation: Perform IP67 water immersion test, confirm no water ingress inside the load cell body, all electrical insulation performance remains intact
  8. Final Documentation: Record all test metrics and calibration data in the official ABB quality log, assign unique serial number traceability tag, and issue formal calibration certification report before shipment

 

New Module Installation Guidelines

  1. Pre-Installation Preparation: Confirm the production line is in safe maintenance state, wear certified ESD wrist strap connected to the machine grounding point before handling the load cell, avoid any impact or overload force on the force sensing element
  2. Mounting Fixture Installation: Secure the dedicated ABB standard mounting bracket on the production line frame, ensure the mounting surface flatness is ≤0.1mm to eliminate installation stress that affects measurement accuracy
  3. Load Cell Mechanical Mating: Carefully install the 1.0KN load cell on the mounting bracket, lock the 4 M6 mounting screws to recommended torque of 1.2Nm, confirm the force application direction is strictly aligned with the marked load direction arrow
  4. Signal Cabling Connection: Connect the shielded 4-core signal cable between the load cell and PFEA tension controller, strictly separate low-level tension signal cables from high-power VFD motor cables to eliminate electrical interference
  5. Power-Up and Initial Calibration: Restore 24V DC power supply, perform zero point calibration in the PFEA tension controller, confirm the no-load tension reading shows 0N within 10 seconds
  6. Full Production Line Validation: Run the production line at different operating speeds, confirm the tension measurement value remains stable, no abnormal fluctuation or signal dropout occurs before transferring the production line to normal operation mode

 

Application Scenarios and Features

  • Papermaking Production Lines: Deployed in large-scale papermaking machine wet end and dry end sections, providing high-precision tension control for paper web during high-speed operation, eliminating paper breakage and web wrinkle defects
  • High-Speed Printing Production Lines: Used in gravure and flexographic printing machines, maintaining constant tension for thin film and paper substrates, preventing color registration deviation and material stretching deformation
  • Packaging Material Production: Applied in plastic film and aluminum foil composite production lines, ensuring uniform tension during unwinding and winding processes, improving finished product flatness and yield
  • Metal Strip Processing: Deployed in steel and aluminum strip rolling production lines, stabilizing strip tension during high-speed rolling, reducing thickness deviation and surface scratch defects
  • Textile Fiber Production: Used in high-speed chemical fiber spinning and weaving production lines, controlling yarn unwinding tension accurately, reducing yarn breakage and fabric defect rate
  • Legacy Tension System Modernization: Acts as the official drop-in replacement for older ABB PFTL101 series load cells, preserving all existing mounting fixtures and tension controller configuration to minimize production line downtime during hardware replacement

 

Frequently Asked Questions

  1. Q: My load cell reports “Tension Reading Drift” after installation, what is the most common root cause?
    A: 90% of this fault is caused by improper installation stress. First check the mounting bracket flatness and screw torque, then re-perform zero point calibration in the PFEA tension controller.
  2. Q: Can I replace an older 1.0KN unit with a new unit directly without re-calibration?
    A: No, you must perform full zero point and span calibration after replacement to ensure the measurement accuracy meets the ±0.1% full scale specification.
  3. Q: What is the maximum allowable overload force this load cell can withstand without permanent damage?
    A: The 1.0KN can safely withstand 150% of 1.0kN (1500N) overload force without permanent mechanical deformation or measurement performance degradation.
  4. Q: Does this load cell support high-pressure water jet on-site cleaning?
    A: Yes, the IP66/IP67 ingress protection rating allows direct low-pressure water jet cleaning on site, fully meeting the strict hygiene requirements of food and pharmaceutical production lines.