SIEMENS MOORE 16137-188 — APACS+ / QUADLOG Redundant ACM/LIM Cable, 2 Meter, Interprocessor Redundancy Link for the Moore DCS

Related Product Recommendations

Model Description
16137-189 ACM redundancy cable, 1 m (3.3 ft)​ — the short in-rack partner to this part
16137-221 ACM-to-ACM serial redundancy cable (distinct from the ACM/LIM link; verify before ordering)
16137-151 / 16137-153 M-Bus “A” / “B” side cables, 4 m — the Module Bus pair
16137-152 / 16137-154 M-Bus “A” / “B” side cables, 15 m
16137-173 / 16137-176 M-Bus “A” / “B” termination plugs (bus-end terminators)
16137-172 / 16137-175 MBI A / B side cable kits for custom drop lengths
16137-186 / 16137-187 Modulbus “A” / “B” side extension cables
16137-145 / 148, 146 / 149, 147 / 150 I/O Bus “A” / “B” cables, 4 m / 15 m / 30 m
16139-xxx / 39ACM… Advanced Control Modules (ACM) served by this cable
16114-171 / 16114-500 MODULERAC Rack chassis housing the ACM / LIM / I/O modules
Siemens PCS 7 Documented migration target for end-of-life APACS+ / QUADLOG
Category: Brand:

Description

SIEMENS MOORE 16137-188 — APACS+ / QUADLOG Redundant ACM/LIM Cable, 2 Meter, Interprocessor Redundancy Link for the Moore DCS

16137-188

Brand & Model Title

Siemens Moore (Moore Products Co. heritage) 16137-188 — APACS+ / QUADLOG Cable, Redundant ACM/LIM, 2 m, Factory-Terminated Interprocessor Redundancy Link Between Advanced Control Module and Link Interface Module

The 16137-188 is not a module — it is a pre-terminated redundancy link cable in the Moore APACS+ / QUADLOG controller architecture. The OEM catalog description reads exactly “CABLE, REDUNDANT ACM/LIM, 2M” ​: a two-metre assembly that ties an ACM (Advanced Control Module — the controller) into the LIM (Link Interface Module) redundancy path, so that either controller of a redundant pair can drive either link interface. Its short-length sibling is the 16137-189 (1 m, ACM redundancy cable, 3.3 ft), which serves adjacent-slot pairs inside the same rack; the 16137-188 covers the 2 m span between adjacent racks or across a cabinet partition.

 

Main Technical Specifications

Parameter Value
Product type Factory-terminated shielded redundancy cable assembly (passive interconnect)
Function ACM ↔ LIM redundant-path / interprocessor communications link
Platform Moore APACS+ and QUADLOG DCS
Length 2 m (6.6 ft)​
Short variant 16137-189 — ACM redundancy cable, 1 m (3.3 ft)
Connectors OEM keyed multi-pin, factory crimped, locking latches; end-to-end pin-for-pin redundant link
Cable construction Shielded twisted construction, impedance-controlled, flame-retardant jacket, moulded strain relief
Weight 0.41 kg / 0.90 lb (shipping weight, distributor record)
Commercial codes ASPN SIE16137-188; UPC / GTIN 662643362770; UNSPSC 26121620
Country of origin Mexico (Siemens-channel record); historically US (Moore, Spring House, PA)
Lifecycle Discontinued by manufacturer — surplus / refurbished supply only
Indicative price ≈ USD 120–260 depending on condition and channel (2026 surplus market)

 

Typical Applications

  • Redundant controller pairs — the physical redundancy channel between the primary and standby ACM and their respective LIMs, allowing a controller swap-over without re-cabling
  • ACM / LIM rack builds and swaps — re-cabling after MODULERAC chassis replacement or when a controller pair is re-arranged between adjacent racks (the 2 m span is the practical limit for this)
  • Cabinet re-partitioning — where the ACM pair and the LIM/IO section end up in neighbouring enclosures but within a 2 m cable run
  • Fault recovery on redundancy alarms — replacing a cable with cracked jacket, bent or recessed pins, or a fatigued conductor-to-connector crimp, which presents as intermittent partner-comms or redundancy faults
  • Legacy life extension and spares holding in refining, petrochemical, power, pulp & paper and water treatment plants kept online pending migration to SIMATIC PCS 7

 

Related News & Events

  • Correct identity, widely mislabelled. The dominant search results describe 16137-188 as a “Yokogawa 32-channel 24 VDC digital input module” ​ with IP65 rating, RS-485/Modbus and 1 km transmission claims — complete fabrication. Others render it as a generic “Yokogawa redundant communication cable” with invented conductor sizes (2.5 mm², PE insulation, red jacket) and invented CE/UL/RoHS certification. The only verifiable description is the OEM one: a 2 m redundant ACM/LIM cable.
  • Length discrepancy to watch. One large US surplus house lists this part with the description “Interprocessor Communications Cable 3.3 Ft (1 m)​” — that is the description of the 16137-189, evidently mis-mapped. Two independent Siemens-channel records (authorized distributor listing and a national reseller) both give 2 m and the OEM string “2M”. Order by part number and verify the length on the cable label.
  • The “16056-593” cross-reference is a distributor artifact, not a Moore number — it appears as the “model type” on several unrelated Moore APACS pages at the same reseller (including 16137-158 and 16137-189). Do not use it as a search key; it will return the wrong items.
  • Distinguish from the ACM-to-ACM serial cable. Field engineers rebuilding a redundant pair report the dedicated serial redundancy cable as 16137-221, which is a different assembly from the 16137-188 ACM/LIM link. Buying the wrong one leaves the pair unable to synchronise, and no pinout documentation is published — Siemens support no longer answers on this platform, so the connector keying on the installed cable is the only reliable reference.
  • Lifecycle position:​ APACS+ / QUADLOG is fully discontinued; remaining stock is new-surplus or refurbished, typically carrying a 1–2 year reseller warranty rather than an OEM one. The documented forward path remains migration to SIMATIC PCS 7.