Description
SIEMENS MOORE 16137-153 — APACS+/QUADLOG M-Bus “B” Side Cable, 4 Meter, Shielded Pre-Terminated Module Bus Interconnect

16137-153
Brand & Model Title
Siemens Moore (Moore Products Co. heritage) 16137-153 — APACS+ / QUADLOG Cable, M-Bus “B” Side, 4 m, Shielded Pre-Terminated Module Bus Cable Assembly (Redundant Channel)
The 16137-153 is a cable assembly, not a module — a factory-built, pre-terminated shielded interconnect of the Moore APACS+ / QUADLOG bus architecture. In the 16137 cable catalog the 14x/15x block is organised as strict A/B-side × length triplets: 16137-151 / 152 = M-Bus “A” at 4 m / 15 m, and 16137-153 / 154 = M-Bus “B” at 4 m / 15 m (with 16137-158 covering the 2 m “B” span and 16137-222 / 223 the 2.5 m A/B pair). The catalog description reads simply “CABLE, M-BUS, B-SIDE, 4M” . So the 16137-153 is the 4-metre redundant (“B”) channel of the Module Bus, whose mandatory primary counterpart is the 16137-151 on the “A” side.
Main Technical Specifications
| Parameter | Value |
|---|---|
| Product type | Pre-terminated shielded bus cable assembly (passive interconnect) |
| Function | M-Bus (Module Bus) “B” side — redundant channel |
| Platform | Moore APACS+ and QUADLOG DCS |
| Length | 4 m (13.1 ft) |
| Matching “A” side | 16137-151 (4 m) · 16137-152 (15 m) |
| Longer “B” variant | 16137-154 (15 m) · shorter: 16137-158 (2 m) |
| Bus-end terminator | 16137-176 (M-Bus “B” termination plug); “A” side uses 16137-173 |
| Connectors | OEM keyed / polarised, factory crimped, mis-mate protected, locking latches |
| Cable construction | Shielded, impedance-matched to the APACS+ bus spec; flame-retardant industrial jacket with strain relief |
| Bus rule | A and B paths are independent; equal length is not required — both must be intact and terminated at both extremes |
| Commercial codes | ASPN SIE16137-153; UPC / GTIN 662643362664; UNSPSC 26121620 |
| Country of origin | Mexico (Siemens-channel record); historically US (Moore, Spring House, PA) |
| Lifecycle | Discontinued — spare / surplus supply only |
Typical Applications
- Redundant Module Bus path in APACS+ / QUADLOG cabinets — installed as the “B” channel, physically and logically separate from the 16137-151 “A” cable, so a single-path failure does not take down controller-to-I/O communication
- ACM ↔ MODULERAC / IEM interconnect — 4 m covers adjacent-rack and short in-cabinet runs between the Advanced Control Module pair, I/O nests and mounted interface hardware
- Re-cable and rack-swap work — replacement after 16114-series MODULERAC chassis change-out, cabinet re-arrangement, or where the original cable shows jacket cracking, bent pins or a fatigued crimp
- Legacy life extension in refining, petrochemical, power, pulp & paper and water treatment, where the host system is kept online pending a PCS 7 or S7-400 migration
- Spares holding — the cable most often consumed in a bus-fault troubleshooting kit, alongside its A-side partner and two terminators
Related News & Events
- The part number is the specification. Side and length are encoded in the suffix, which is why the block can be ordered without a datasheet. The trap is ordering an A-side number for a B-side port: the connectors are keyed, but the two paths are wired differently, so a mis-ordered cable is a non-starter at commissioning, not a field-modifiable item.
- Fabricated listings dominate the search results. This number is widely mislabelled — most aggressively as a “Yokogawa 16137-153 high-precision process control module”, and elsewhere as a S7-300 backplane/rail ModuleBus cable (“connects S7-300 modules to the backplane of the rail”), which is entirely spurious. Sibling numbers are similarly abused (16137-174 resold as “Bently Nevada”). None of these descriptions originate from a Siemens document; treat any page describing 16137-153 as a module, card or S7-300 accessory as AI-generated content.
- Naming collision worth knowing: “M-Bus” here is the Moore/Siemens proprietary Module Bus, unrelated to the European EN 1434-3 meter bus of the same name. Generic RS-485 or metering-bus cable is not a substitute — the APACS terminator is matched to both characteristic impedance and DC bias.
- Field-proven fault behaviour: an APACS MBUS fault is latched in the ACM’s diagnostic logic. Re-seating the B cable restores the physical layer but does not clear the alarm; recovery in practice requires a controlled power-down/power-up of the redundant ACM pair. Plan any B-side re-cable for a scheduled outage, run a loop check, and confirm both ACMs hold steady green for at least five minutes before returning loops to automatic.
- Lifecycle position: APACS+ / QUADLOG is long out of Siemens production support; QUADlog technology was also licensed into Yokogawa ProSafe-PLC, which is why these cables surface under Siemens, Moore and occasionally Yokogawa labels. Supply is new-surplus or tested-used, and the official forward path is migration to SIMATIC PCS 7.