HIMA F8650X SIL3 Safety Central CPU Module for H51q / H41q PES System

  1. HIMA F8652X Safety CPU Module
  2. HIMA F8650E Central CPU Module
  3. HIMA F8627X Safety Communication Module
  4. HIMA F3110 Digital Input Module
  5. HIMA F3210 Digital Output Module
  6. HIMA F3330 Analog Input Module
  7. HIMA F8010 Rack Power Supply Module
  8. HIMA F8621 Serial Communication Card

 

Category: SKU: HIMA F8650X SIL3 Brand:

Description

HIMA F8650X SIL3 Safety Central CPU Module for H51q / H41q PES System

 

Executive Summary

The HIMA F8650X is a certified safety central CPU module designed for HIMA H51q and H41q programmable electronic safety systems. It adopts dual lockstep 32-bit Intel 386EX processor architecture, dedicated to executing safety application logic, processing field I/O signals, managing system diagnostics and internal bus communication. With SIL3 certification complying with IEC 61508 & IEC 61511, it integrates 4-digit matrix diagnostic display, dual electrically isolated RS485 ports and safety watchdog output. Hot-swap capability enables on-line maintenance without system shutdown. Widely used for ESD, F&G, BMS and turbomachinery protection within oil, gas, chemical and power industries.

 

Core Technical Specifications

  • Manufacturer: HIMA Paul Hildebrandt GmbH (Germany)
  • Model: F8650X, Order Code:984865065 / 984865066
  • Compatible Platform: H51q-MS / H51q-HS / H51q-HRS & H41q safety PES
  • Safety Certification: SIL3 (IEC 61508, IEC 61511)
  • Processor: Dual 32-bit Intel 386EX lockstep CPU, 25MHz
  • Memory: 1MB Flash-EPROM for OS, 1MB Flash-EPROM for user safety program, 1MB SRAM data memory
  • Communication: 2 x electrically isolated RS485 serial interfaces for safety backplane bus
  • Front Panel: 4-digit matrix diagnostic display + multi-status LED indicators
  • Watchdog: 24VDC safety watchdog output, max 500mA, short-circuit protected
  • Form Factor: 8SU European standard double PCB card
  • Power Consumption: 5VDC, 2A via rack backplane
  • Operating Temperature: 0℃ ~ +60℃
  • Storage Temperature: -40℃ ~ +85℃
  • Relative Humidity: ≤95%, non-condensing
  • Protection Class: IP20
  • Backup Battery: CR2477N for real-time clock & data retention
  • Weight: Approx. 0.32kg

 

Main Features & Advantages

  1. Dual lockstep fault-tolerant architecture: Synchronous operation of two processors with continuous cross-comparison. The system will switch to safe state once mismatch is detected.
  2. TÜV SIL3 certification: Meets functional safety requirements for high-risk process safety instrumented systems.
  3. Comprehensive onboard self-diagnostics: Continuously monitors CPU, memory, bus, power and I/O channels. Fault codes shown on front panel for rapid troubleshooting.
  4. Isolated dual RS485 ports: Reinforces noise immunity in heavy electromagnetic interference industrial sites, connecting local I/O modules.
  5. Hot-swap support: Module replacement while safety system remains online, minimizing plant downtime.
  6. Hardware safety watchdog: Hardware-level fail-safe mechanism to cut safety outputs and trigger predefined safe state upon internal fault.
  7. Compact 8SU European card design: Simple rack installation, fits standard HIMA safety chassis.
  8. Stable deterministic execution: Fixed scan cycle for safety logic, guaranteeing consistent response time for safety interlock actions.

 

Application Scenarios

  • Emergency Shutdown System (ESD) for refineries, offshore oil & gas platforms
  • Fire and Gas (F&G) hazard monitoring & protection systems
  • Boiler and Burner Management System (BMS) safety interlock
  • Gas turbine, steam turbine and compressor machinery protection
  • Power plant safety interlock and protection control
  • LNG terminal and storage tank safety instrumented systems
  • Fine chemical and pharmaceutical plant safety shutdown control

 

Recommended Related Models (8pcs)

  1. HIMA F8652X Safety CPU Module
  2. HIMA F8650E Central CPU Module
  3. HIMA F8627X Safety Communication Module
  4. HIMA F3110 Digital Input Module
  5. HIMA F3210 Digital Output Module
  6. HIMA F3330 Analog Input Module
  7. HIMA F8010 Rack Power Supply Module
  8. HIMA F8621 Serial Communication Card

 

FAQ

Q1: What safety level does HIMA F8650X achieve? A: It holds SIL3 certification per IEC 61508 / IEC61511, applicable to safety loops up to SIL3.

Q2: Which HIMA safety systems is F8650X compatible with? A: It serves as the main central module for HIMA H51q and H41q series programmable electronic safety systems.

Q3: Does F8650X support hot swap? A: Yes. Hot-swap is available. Operators can replace the module without stopping the safety system.

Q4: What is the function of the watchdog output? A: The 24V watchdog output is a safety-related hardware signal. If CPU fault occurs, the watchdog will de-energize the output and force the whole system into safe state.

A: It belongs to legacy HIMA H51q series. Original new production has ceased. Available stock is original factory spare inventory.

Q6: What are the RS485 ports used for? A: The dual isolated RS485 interfaces are dedicated internal safety bus for communication between CPU and HIMA I/O modules, not for direct connection to general HMI.

A: No. To maintain SIL certification, only original certified HIMA I/O modules are permitted for system configuration.

Q8: What is the service cycle of the backup battery? A: The CR2477N battery retains RTC and memory data. Recommended replacement cycle is 4 years.