Bently Nevada 3500/15-01-01-00 (125840-02) AC Power Supply Module

Related Model Recommendations

  1. ‌Bently Nevada 3500/15-02-00-00‌: High Voltage DC Power Supply Module (48-125 VDC), for facilities with higher voltage DC distributions.
  2. ‌Bently Nevada 3500/15-04-00-00‌: Low Voltage DC Power Supply Module (20-30 VDC), for facilities utilizing 24 VDC control power systems.
  3. ‌Bently Nevada 3500/22M‌: Transient Data Interface (TDI) Module, essential for system communication and configuration.
  4. ‌Bently Nevada 3500/42M‌: Proximitor Monitor Module, a common load powered by the 3500/15.
  5. ‌Bently Nevada 3500/32‌: Relay Output Module, for alarm and trip actuation.
  6. ‌Bently Nevada 3500/92‌: Communication Gateway Module, for integrating with DCS/SCADA systems.
  7. ‌Bently Nevada 3500/04‌: Earthing I/O Module, required for grounding internal barriers in hazardous area modules.
  8. ‌Bently Nevada 3500 Rack Chassis‌: The physical enclosure required to house the power supply and monitor modules.

 

Category: Brand:

Description

Bently Nevada 3500/15-01-01-00 (125840-02) AC Power Supply Module

Product Core Introduction

The Bently Nevada 3500/15-01-01-00, incorporating the internal power supply unit part number 125840-02, is a half-height AC Power Supply module designed for the Bently Nevada 3500 Machinery Protection System. It converts standard universal AC input voltage into regulated low-voltage DC power required to operate all monitor and interface modules within the 3500 rack chassis.

Specifically configured with the “01” option, this module accepts a wide-range AC input of 85 to 132 VAC rms (50/60 Hz), making it suitable for global industrial applications where standard low-voltage AC power is available. The module supports redundant configuration, allowing two power supplies to be installed in a single rack to ensure continuous, uninterrupted operation of critical machinery protection systems in power generation, oil & gas, and chemical processing facilities. Its robust design ensures high reliability and compliance with industrial safety standards.

 

Primary Technical Specifications

  1. ‌Official Part Number‌: 3500/15-01-01-00
  2. ‌Internal Component P/N‌: 125840-02 (AC Power Supply Unit)
  3. ‌Product Family‌: Bently Nevada 3500 Series Machinery Protection System
  4. ‌Module Type‌: Half-Height AC Power Supply
  5. ‌Input Voltage Range‌: 85 to 132 VAC rms (Universal Low Voltage AC), 50/60 Hz
  6. ‌Output Voltage‌: Regulated 24 VDC for 3500 Rack Backplane
  7. ‌Maximum Current Draw‌: 2.8 A rms at maximum load
  8. ‌Redundancy Support‌: Supports dual power supply configuration (Primary/Backup) in a single rack
  9. ‌Installation Slot‌: Must be installed in designated power supply slots on the left side of the 3500 rack
  10. ‌Physical Dimensions‌: 120.7 mm (H) × 50.8 mm (W) × 251.5 mm (D) / 4.75 in × 2.0 in × 9.9 in
  11. ‌Weight‌: 1.39 kg (3.06 lbs)
  12. ‌Agency Approval‌: Standard industrial compliance (Option 00 indicates no specific additional agency approval in this configuration code, though the base module meets general industrial standards)

 

Configuration Code Breakdown (3500/15-01-01-00)

  • ‌3500/15‌: Power Supply Module Family
  • ‌01‌: Top Slot Power Supply Type = Low Voltage AC (85-132 VAC)
  • ‌01‌: Bottom Slot Power Supply Type = No Supply (This is a single half-height module; if a second module were present in the lower slot, this code would define it. In a single-module setup, the second digit is often ’00’ or ’01’ depending on ordering convention for empty slots, but here it denotes the specific configuration ordered). Note: Typically, a single module order might be 3500/15-01-00-00. The 3500/15-01-01-00 configuration implies a specific dual-slot definition or a kit, but physically it is one half-height module. The second ’01’ often refers to the bottom slot being configured for a matching supply if ordered as a pair, or it is a specific ordering variant. For a single physical module, the key identifier is the first ’01’ for AC input.
  • ‌00‌: Agency Approval Option = None/Standard

(Note: The part number 125840-02 refers to the specific internal AC power supply component or assembly within the 3500/15 module housing.)

 

Quality Control Procedures

Every Bently Nevada 3500/15 power supply module undergoes rigorous testing to ensure reliability in critical applications:

  1. ‌Input Voltage Stress Testing‌: Modules are tested across the full 85-132 VAC input range to ensure stable 24 VDC output under varying line conditions and frequencies (50/60 Hz).
  2. ‌Load Regulation Verification‌: Each unit is verified to maintain output voltage within tight tolerances under full rack load conditions, ensuring all connected monitors receive stable power.
  3. ‌Redundancy Switchover Testing‌: For systems with dual supplies, the seamless transfer from primary to backup power is validated to ensure zero interruption to monitor modules during a primary supply failure.
  4. ‌Thermal Performance Validation‌: Modules undergo thermal cycling to ensure reliable operation within the specified industrial temperature range (-40°C to +85°C storage, 0°C to +65°C operating).
  5. ‌Safety Compliance Testing‌: Electrical isolation, leakage current, and safety standards are verified to protect both equipment and personnel.

 

Related Model Recommendations

  1. ‌Bently Nevada 3500/15-02-00-00‌: High Voltage DC Power Supply Module (48-125 VDC), for facilities with higher voltage DC distributions.
  2. ‌Bently Nevada 3500/15-04-00-00‌: Low Voltage DC Power Supply Module (20-30 VDC), for facilities utilizing 24 VDC control power systems.
  3. ‌Bently Nevada 3500/22M‌: Transient Data Interface (TDI) Module, essential for system communication and configuration.
  4. ‌Bently Nevada 3500/42M‌: Proximitor Monitor Module, a common load powered by the 3500/15.
  5. ‌Bently Nevada 3500/32‌: Relay Output Module, for alarm and trip actuation.
  6. ‌Bently Nevada 3500/92‌: Communication Gateway Module, for integrating with DCS/SCADA systems.
  7. ‌Bently Nevada 3500/04‌: Earthing I/O Module, required for grounding internal barriers in hazardous area modules.
  8. ‌Bently Nevada 3500 Rack Chassis‌: The physical enclosure required to house the power supply and monitor modules.

 

Brand Development History

Bently Nevada, now part of Baker Hughes, has been the global leader in machinery protection for over 60 years. The 3500 Series was introduced as a modular, flexible, and highly reliable platform for monitoring critical rotating equipment. The 3500/15 Power Supply module was designed to provide robust power options for this system, accommodating various industrial power standards including AC, Low Voltage DC, and High Voltage DC. The 3500/15-01-01-00 variant specifically addresses the needs of facilities utilizing standard 110/120 VAC power systems, ensuring compatibility and reliability in diverse global industrial environments.

 

Frequently Asked Questions

  1. ‌Q: What is the input voltage range for the 3500/15-01-01-00 module?‌
    A: The “01” configuration indicates a Low Voltage AC input range of 85 to 132 VAC rms, suitable for 110/120 VAC nominal systems worldwide.
  2. ‌Q: Can I install two 3500/15-01-01-00 modules in one rack for redundancy?‌
    A: Yes, you can install two power supply modules in a single 3500 rack. The lower slot acts as the primary supply, and the upper slot acts as the backup. Both can be the same type (AC/AC) or different types (e.g., AC/DC) depending on availability and requirements.
  3. ‌Q: What does the part number 125840-02 refer to?‌
    A: 125840-02 is the specific part number for the AC power supply component or assembly used within the 3500/15-01-01-00 module housing.
  4. ‌Q: Is the 3500/15 module hot-swappable?‌
    A: Yes, the 3500/15 power supply module is designed for hot-swapping. If a redundant backup supply is installed, the primary supply can be replaced without shutting down the system. Even with a single supply, careful replacement may be possible depending on system criticality, but redundancy is recommended for live maintenance.
  5. ‌Q: Where must the 3500/15 module be installed in the rack?‌
    A: The 3500/15 power supply modules must be installed in the designated power supply slots located on the left side of the 3500 rack chassis.