Description
Allen‑Bradley 1746‑IG16 SLC 500 16‑Point 5VDC TTL Digital Input Module
Meta Description
Original Allen‑Bradley 1746‑IG16 SLC 500 16‑point 5VDC TTL level digital input module, for encoder, TTL pulse and low‑voltage logic signals, discontinued legacy SLC specialty input spare. We operate 86 shared warehouses globally, so it may take several hours to deliver an accurate quotation; thank you for your understanding, and we will handle your inquiry promptly.

1746-IG16
Product Brief Introduction
The 1746‑IG16 is a single‑slot 16‑channel TTL‑level digital input module for the Allen‑Bradley SLC 500 PLC platform. It is designed for 5VDC logic signals, compatible with TTL devices, incremental encoder TTL outputs, high‑speed pulse signals and low‑voltage logic boards, rather than standard 24VDC sensors. It supports both sinking and sourcing TTL signals, with optical isolation and built‑in filtering, and individual LED status indicators for each channel for quick diagnostics. This is a special low‑voltage input card, not the common 24VDC I/O. Rockwell has discontinued the 1746‑IG16; stock is limited for maintenance and spare replacement of legacy machines with TTL signal interfaces. We operate 86 shared warehouses globally, so it may take several hours to deliver an accurate quotation; thank you for your understanding, and we will handle your inquiry promptly.
Main Technical Specifications
- Part Number: 1746‑IG16
- Manufacturer: Allen‑Bradley / Rockwell Automation
- Platform: SLC 500
- Type: TTL Digital Input Module
- Channel Count: 16 points
- Nominal Input Voltage: 5 VDC TTL level
- Input Logic: TTL compatible, sink / source capable
- Response Delay: Max 8 ms on / off
- Isolation: 500VDC between backplane and field side
- Backplane Current Draw: 85 mA @ 5.1 VDC
- Indicators: Individual LED per channel
- Operating Temperature: 0 °C to +60 °C
- Storage Temperature: −40 °C to +85 °C
- Relative Humidity: 5–95 %, non‑condensing
- Certifications: UL, cULus, CE
- Lifecycle Status: Discontinued
- Warranty: 1 year
- Compatibility: Local chassis and remote I/O racks with 1747‑ASB adapter
Quality Control Procedure
Each 1746‑IG16 legacy TTL input module goes through our specialty I/O inspection workflow. We inspect housing, terminal block, locking latch and label integrity. Functional testing applies 5VDC TTL logic levels to each channel sequentially to verify on/off response and LED status, and confirm stable backplane communication inside the SLC rack. Modules with dead channels, flickering LEDs or unstable triggering are rejected. Passed units are packed with anti‑static shielding, and test records are retained for traceability. Please note if you submit a quote request: We operate 86 shared warehouses globally, so it may take several hours to deliver an accurate quotation; thank you for your understanding, and we will handle your inquiry promptly.
FAQ
A: It is a 16‑point 5VDC TTL input module for SLC 500, used for TTL encoders, TTL pulse and low‑voltage logic signals, not for normal 24VDC sensors.
A: = 5VDC TTL level input; IB16 = 24VDC sinking DC input for standard NPN sensors.
A: No, it is rated for 5V TTL only. 24VDC signals will damage this module.
Q: Can it be used in remote I/O racks? A: Yes, it supports both local chassis and remote racks controlled by 1747‑ASB.
Q: Is this module still in production? A: No, Rockwell discontinued this part. Stock is limited surplus inventory only.
Q: When will I receive my quotation? A: We operate 86 shared warehouses globally, so it may take several hours to deliver an accurate quotation; thank you for your understanding, and we will handle your inquiry promptly.
Installation & Configuration Guide
Slide the 1746‑ into an empty slot of a 1746 chassis and lock the latch. Wire TTL encoders or 5V logic signals strictly following the TTL common layout, do not feed 24VDC. Power up the rack and 5V field supply. In RSLogix 500, the module is automatically recognized as a 16‑point input card. Toggle each TTL signal and confirm the corresponding channel LED and PLC input bit change state. Follow Rockwell’s user manual and local electrical codes.
Relevant News & Events
The 1746‑ is a niche TTL input card for SLC 500, commonly used for reading TTL‑output encoders on older positioning machines and custom control boards. It is less common than 24VDC IB/IV series cards, so spare stock is harder to source. For new projects, TTL signals are usually read via high‑speed counter modules or Compact 5000 specialty I/O.
Application Scenarios & Functional Advantages
Typical Use Cases
- TTL incremental encoder pulse acquisition
- 5VDC logic board status and handshake signals
- Low‑speed TTL pulse counters and custom interface boards
- Legacy positioning machine TTL signal replacement
- SLC 500 remote I/O rack expansion for TTL signals
- Replacement spare for failed 5V TTL input cards
Key Advantages
- Dedicated 5V TTL logic level input interface
- Supports both sinking and sourcing TTL signals
- Optical isolation and filter circuit for anti‑interference
- Individual LED status for fast field troubleshooting
- Supported in local and remote SLC I/O racks
- Simple configuration, no special setup required
Recommended Related Part Numbers
- 1746‑IB16: 16‑point 24VDC sinking input
- 1746‑IV16: 16‑point 24VDC sourcing input
- 1746‑HSCE: High‑speed counter / encoder module
- 1747‑ASB: Remote I/O adapter
- 1747‑L552: SLC 5/05 processor
- 1746‑A7 / 1746‑A10: SLC chassis