Model Description
BMXSDO0802 X80 8-point safety discrete output module — official replacement (2 units per 16-point swap)
140SDI95300S Quantum safety DC discrete input module — the matching 16-point safety input side
140 CPU 651 50S / 140 CPU 658 60S Quantum safety CPUs required to configure this module (Unity Pro Safety)
140CPS12420 Quantum rack power supply for safety racks
BMXSDI1602 X80 safety discrete input module — companion replacement on the X80 platform
Modicon M580 Safety (BMEH58…) + X80 Recommended migration platform for SIL-rated applications
Category: Brand:

Description

140SDO95300S — Schneider Electric Modicon Quantum Safety DC Discrete Output Module (16 Outputs, 19.2–30 V DC)

140SDO95300S

Brand & Model Title

Schneider Electric 140SDO95300S — Modicon Quantum Safety DC Discrete Output Module, 16 Channels, 19.2…30 V DC, TÜV Rheinland SIL2-Certified

The 140SDO95300S is the safety-rated digital output module of the Modicon Quantum safety platform — the “safety execution terminal” paired with the 140SDI95300S safety input module. It drives safety-related actuators (trip valves, shutdown relays, contactors, alarms) with source-type (positive logic) 24 V DC outputs, and enforces fail-safe behavior: on overload, power fault, or internal channel failure, affected outputs are forced to their safe state and the fault is reported to the controller. Like all “S” modules, it can only be configured with a Quantum safety CPU under Unity Pro Safety.

 

Main Technical Specifications

Parameter Value
Product type Safety DC discrete output module
Platform Modicon Quantum automation platform (safety architecture)
Outputs 16 discrete outputs, 1 group, positive logic (source)
Output voltage 19.2…30 V DC; absolute maximum output 34 V
Load current ≤ 0.65 A per point; ≤ 10.04 A per group; inrush 2 A for 10 ms
Voltage drop / leakage < 0.3 V @ 0.5 A; leakage ≤ 0.5 mA @ 30 V
Sensor power supply 19.2…30 V DC
Response time ≤ 20 ms (0→1 and 1→0)
Addressing requirement 4 output words + 7 input words (diagnostic data)
Fault storage Channel fault, overload, power fault, system fault
Protection External fuse 10 A (with relay); inductive loads require L = 0.5/(I² × f) suppression
Isolation Channel-to-bus 1500 Vrms (1 min); group-to-bus 1500 Vrms (1 min)
Power Power dissipation 1.9 W + 0.65 I²; bus current 350 mA @ 5 V DC (backplane)
Local signalling 1 green LED (bus active), 1 red LED (external fault “F”), 16 green LEDs (output status), 16 red LEDs (system failure / channel diagnostics)
Marking CE; Green Premium™ label (RoHS/REACh compliant)
Certifications TÜV Rheinland (SIL2, IEC 61508)​, CSA, CSA HazLoc, UL, C-Tick
Lifecycle Discontinued 26 February 2022; end of standard service 31 December 2029

 

Typical Applications

  • Emergency shutdown systems (ESD)​ — driving trip valves, shutdown relays and isolation contactors in safety instrumented functions
  • Safety instrumented systems (SIS)​ — SIL2 outputs under IEC 61508 within the Quantum safety architecture (Quantum safety CPU + Unity Pro Safety)
  • Safety interlocking — guard-door locks, machine-stop actuators, fire-and-gas output actions in chemical, petrochemical, power and metallurgy plants
  • Critical actuator control — burners, compressor/turbine trip circuits, and other final elements where fail-safe output behavior is mandatory
  • Spare-part replacement for in-service Quantum safety systems through the 2029 support window

 

Related News & Events

  • Official lifecycle status:​ discontinued — stop of production 26 February 2022, with end of standard service on 31 December 2029; official repair and spare support remains available for roughly three more years.
  • Official replacement announced:​ Schneider Electric recommends the BMXSDO0802 (X80 8-point safety discrete output module) as the replacement — note that two BMXSDO0802 units are required to match one 16-point 140SDO95300S, with wiring and I/O-addressing changes in the migration.
  • Safety certification:​ official rating is TÜV Rheinland SIL2; the module’s fail-safe design forces outputs to a defined safe state on detected faults and stores fault records readable via EcoStruxure Control Expert.
  • Migration warnings circulating in the field:​ replacing it with a standard (non-safety) 140DDO/140DDO-series module voids the safety certification and breaks diagnostic behavior; “new surplus” 140SDO95300S remains the only true 1-to-1 hardware swap without logic changes — verify date codes and functional test records.
  • Field engineering notes:​ the module requires a stable 19.2–30 V DC sensor supply (sagging supplies cause persistent fault indication), and slot placement in safety racks must follow the Quantum safety hardware configuration rules.

 

Related Product Recommendations

Model Description
BMXSDO0802 X80 8-point safety discrete output module — official replacement (2 units per 16-point swap)
140SDI95300S Quantum safety DC discrete input module — the matching 16-point safety input side
140 CPU 651 50S / 140 CPU 658 60S Quantum safety CPUs required to configure this module (Unity Pro Safety)
140CPS12420 Quantum rack power supply for safety racks
BMXSDI1602 X80 safety discrete input module — companion replacement on the X80 platform
Modicon M580 Safety (BMEH58…) + X80 Recommended migration platform for SIL-rated applications