Woodward SPM-D11 8440-1713/D Synchronizer & Load Share Controller

  1. 8440-1706 SPM-D11
  2. 8440-1936 easYgen-3500 genset controller
  3. Woodward 505 / 505E turbine governor
  4. 8440-2299 DSLC-2XT load share controller
  5. 8440-2297 DTSC-200A synchronizer
  6. CLS216 Watlow 16-loop temperature controller
  7. CLS204 Watlow 4-loop temperature controller
  8. WAGO 758-873 PFC200 PLC
  9. MCS2000-ECA Warner tension controller
  10. VM600 MPC4 Vibro-Meter vibration protection card
Category: SKU: WOODWARD SPM-D11 8440-1713/D Brand:

Description

Woodward SPM-D11 8440-1713/D Synchronizer & Load Share Controller

 

Product Title

Woodward 8440-1713/D | SPM-D11 Digital Synchronizing & Load Sharing Controller, Panel Mount Generator Paralleling Unit

 

Product Description

8440-1713/D belongs to the classic SPM-D11 family, a microprocessor-based synchronizer and load share controller for synchronous generator paralleling. It automatically matches voltage, frequency and phase angle between generator and busbar before breaker closure. Supports isochronous / droop kW & kVAR load sharing for multiple gensets. It outputs analog trim signals to engine governor and generator AVR for speed and voltage adjustment. It integrates out-of-sync blocking protection, voltage/frequency monitoring, breaker control logic. Local operation via front LCD & keypad; full parameter configuration and backup through Woodward SPM-D11 PC software. The suffix /D indicates hardware/ firmware variant, defined CT/PT input rating and option package. Widely used for marine power station, island microgrid, CHP and multi-generator industrial prime/backup power.

 

Technical Specifications

 

Item Parameter
Brand Woodward (伍德沃德)
Model SPM-D11, P/N:8440-1713/D
Mounting Panel mount, 144×72 mm DIN 43700 cutout
Power Supply 9.5 ~ 32 VDC (nominal 12/24 VDC)
Max Power Consumption 12 W
PT Measuring Input 100 VAC / 400 VAC (model variant defined)
CT Measuring Input 1 A or 5 A (depends on suffix /D configuration)
Frequency Range 40 ~70 Hz (50/60 Hz systems)
Accuracy Class 1
Control Output Analog ±0~10V trim for governor speed & AVR voltage
Relay Outputs Potential-free relay contacts for breaker, sync permissive, alarms
Communication RS485 Modbus RTU
Operating Temperature -20°C ~ +70°C
Storage Temperature -40°C ~ +85°C
Humidity 5~95% non-condensing
Front Protection IP42, IP54 with gasket fitted
Certifications CE, UL/cUL
Weight Approx. 0.8 kg
Diagnostics Loss of voltage, phase imbalance, CT/PT wiring fault, out-of-sync interlock

 

Compatibility & Installation Pitfalls

Compatibility

  • Equipment:Diesel / gas synchronous generators
  • Partner controls:Woodward 505 / 505E turbine governor, generator AVR, easYgen genset controllers
  • Sensors:Voltage transformer PT, Current transformer CT
  • Host:PLC / SCADA via Modbus RTU
  • Not compatible:SPM-D10 old generation; cannot fully replace all-in-one easYgen-3500 (8440-1936)

Critical Installation Pitfalls

  1. CT safety rule: Short CT secondary terminals before disconnecting wiring. Open CT secondary will generate lethal high voltage.
  2. Verify suffix /D configuration: 8440-1713/D CT/PT rating must match site transformers; mismatched CT/PT causes wrong power reading and load share imbalance.
  3. Analog load-share bus: Load sharing interconnection cable must use shielded twisted pair, separate routing away from high power cables to reduce noise.
  4. Parameter backup: Save full configuration file before replacement. Without backup, synchronizing window, droop, load share and protection parameters must be re-programmed.
  5. DC control power: Use battery supply with surge suppression. Do not share circuit with engine starter, voltage dip will reset controller.
  6. Panel gasket: Install sealing gasket to achieve IP54 front protection, prevent cabinet condensation and dust ingress.
  7. Not hot-swappable: De-energize DC control power and implement LOTO before removal. Live removal loses synchronizing & load share protection, risk of generator damage.

 

Standard Operating Procedure (SOP)

  1. Pre-Install Inspection & LOTO Lock out generator high voltage and DC control power. Inspect LCD, keypad and rear terminal block, confirm part number 8440-1713/D. Prepare SPM-D11 PC configuration software.
  2. Panel Mounting Insert into 144×72 panel cutout, fit sealing gasket and secure mounting clips.
  3. PT/CT, Control & Communication Wiring Wire PT voltage, CT current inputs, governor/AVR analog trim outputs, breaker relay outputs and RS485 Modbus. Use shielded twisted pair. Complete insulation and continuity test.
  4. Controller Configuration Set genset rated parameters, synchronizing window, droop / isochronous mode, kW/kVAR load share parameters, alarm and permissive logic. Save configuration file.
  5. Power-Up & Commissioning Apply DC control power. Verify voltage, current and frequency readings. Perform dead bus test, no-load synchronizing test, multi-unit load sharing test. Validate out-of-sync blocking protection.
  6. Runtime Operation & Diagnostics Monitor sync status, load sharing and alarms via front panel or SCADA. Regularly backup configuration file.
  7. Replacement Procedure Execute LOTO. Short CT secondary first, then disconnect all wiring. Remove old . Install spare 8440-1713/D, rewire, restore saved parameters and run full commissioning & protection verification.

 

Application Scenarios

  • Multi-generator paralleling power plants
  • Marine vessel power management and shore power synchronization
  • Island microgrid and peak shaving systems
  • Oil & gas prime power, CHP combined heat & power
  • Industrial multi-set backup power station
  • Retrofit and spare replacement for legacy generator parallel control

 

Supporting Components

  1. 144×72 panel mounting kit and sealing gasket
  2. Current transformer CT & voltage transformer PT
  3. 12/24VDC surge protected battery power supply
  4. PC configuration software
  5. Shielded twisted pair for analog load-share and Modbus wiring
  6. Woodward governor (505/505E) and generator AVR
  7. Circuit breakers and terminal blocks
  8. PLC/SCADA host for remote monitoring
  9. Generator breaker interlock logic
  10. Load-share termination resistors

 

Related Model Recommendations (10 Models)

  1. 8440-1706 SPM-D11
  2. 8440-1936 easYgen-3500 genset controller
  3. Woodward 505 / 505E turbine governor
  4. 8440-2299 DSLC-2XT load share controller
  5. 8440-2297 DTSC-200A synchronizer
  6. CLS216 Watlow 16-loop temperature controller
  7. CLS204 Watlow 4-loop temperature controller
  8. WAGO 758-873 PFC200 PLC
  9. MCS2000-ECA Warner tension controller
  10. VM600 MPC4 Vibro-Meter vibration protection card