Description
Product Core Overview
The Reliance Electric 0-57C402-C is a high-performance industrial DC power supply module belonging to Reliance Electric’s classic 57C series product family (now under Rockwell Automation). As the core low-voltage stable power supply component for Automax PLC systems and GV3000/SE series variable frequency drives, it delivers reliable AC to DC conversion, high-precision voltage stabilization and multi-level safety protection performance. This discontinued industrial spare part is widely deployed in legacy metallurgical rolling mills, papermaking, automotive manufacturing, printing and plastic processing production lines worldwide, and is a critical spare part for many factories to maintain continuous production without full control system renovation. It adopts high-quality power components and redundant protection design, ensuring extremely stable operation even in harsh industrial environments with strong electromagnetic interference and voltage fluctuations.
Key Technical Specifications
- Official Part Number: 0-57C402-C
- Manufacturer: Reliance Electric (acquired by Rockwell Automation)
- Product Type: Industrial-grade DC Power Supply Module
- Product Series: 57C Series
- Core Function: Industrial AC to DC power conversion, low-voltage control system stable power supply
- Input Parameters: 115/230V AC dual-mode adaptive, 50/60Hz; voltage variation range ±20%
- Output Parameters: 24V DC / 10A, stable continuous output
- Control Precision: Voltage stabilization accuracy ≤±0.2%, no obvious drift under full load
- Conversion Performance: Ripple coefficient ≤0.3%; full-load conversion efficiency ≥92%
- Protection Features: Built-in overcurrent protection, overvoltage protection, overheating protection and short-circuit automatic recovery function
- Installation Method: DIN rail installation, compatible with standard industrial control cabinet installation dimensions
- Operating Temperature Range: -10°C to +60°C (no condensation in control cabinet)
- Humidity Resistance: 5–95% RH, no condensation
- Compatible Systems: Natively fully compatible with Reliance Electric Automax series PLC systems and GV3000/SE series variable frequency drives
- Status: Discontinued, Rockwell Automation no longer provides official new unit supply and full technical support
- Typical Application: Provides stable 24V DC power supply for Automax PLC I/O modules, sensor systems, VFD control loops and other low-voltage industrial control equipment
8 Recommended Related Series Models
- 0-57C402-1: Reliance fully compatible 24V DC power supply module, 100% drop-in replacement for 0-57C402-C
- 0-57C400-A: Reliance 57C series high-power 220V DC power supply module, the high-voltage power supply component paired with this low-voltage module
- 0-57407-4H: Reliance Automax series central control processor module, the core control component powered by this power supply module
- 0-57408-B: Reliance Automax series power interface module, the system-level power distribution component paired with this module
- 0-57406-E: Reliance Automax series analog output module, the analog signal output component powered by this power supply module
- GV3000/SE: Reliance classic high-performance variable frequency drive series, the main load device matched with this power supply module
- ABB AC 800M: Distributed Control System, for upper-level DCS system industrial control data collection and processing
- WR-D4007: Reliance redundant power supply module, providing 24V DC redundant power protection for the control system

0-57C402-C
Professional Quality Control Test Standard Operating Procedure
- Pre-Test Visual Audit: Inspect the module PCB for physical damage, corroded power terminals or loose components; confirm all power conversion circuits and protection devices are fully intact
- Input Voltage Adaptation Validation: Apply variable 115/230V AC input across full operating range, verify no overcurrent, overheating or unexpected shutdown occurs
- Output Performance Test: Connect standard industrial load to the module output port, confirm the 24V DC / 10A output performance meets official specifications, no voltage drift or overheating occurs
- Precision Validation: Test voltage stabilization accuracy, ripple coefficient and load regulation rate one by one, confirm all performance indicators meet the industrial high-precision power supply requirements
- Protection Function Validation: Simulate overcurrent, overvoltage, short-circuit and overheating fault scenarios, confirm the module can quickly trigger protection action and automatically recover after fault elimination, no load damage or circuit burnout occurs
- Environmental Temperature Cycling: Place the module in an environmental chamber, run full functional validation across -10°C to +60°C operating range, confirm no performance degradation or unexpected fault trips at extreme temperature limits
- Vibration Resistance Test: Simulate industrial 5–500Hz vibration environment, confirm no loose internal components or unstable power output occurs
- Final Documentation: Record all test metrics and performance data in the quality log, assign unique serial number traceability tag, and issue formal performance certification report before shipment
New Module Installation Guidelines
- Pre-Installation Preparation: Power down the target industrial control system completely, confirm the main AC power input is fully cut off, wear certified ESD wrist strap connected to the chassis grounding point before handling the module
- Installation Position Confirmation: Fix the module on the designated DIN rail in the control cabinet, ensure no adjacent high-power heating components cause long-term overheating impact on the module, and leave enough heat dissipation space around
- Mechanical Mating: Push the module smoothly along the DIN rail until the bottom fixing buckle is locked, confirm the module is firmly fixed without shaking
- Power Cabling Connection: Connect the AC input cable and 24V DC output cable to the corresponding terminals, confirm the wiring is firm and no loose contact exists, strictly separate high-power power cables from low-level signal cables to eliminate electromagnetic interference
- Power-Up and Initial Diagnostic: Restore power supply, observe the module status indicators; confirm the module completes power-on self-check process and enters normal running state within 30 seconds, no overvoltage or overcurrent alarm appears
- Full System Validation: Power on the entire control system and all low-voltage load devices sequentially, confirm all devices can get stable 24V DC power supply and operate normally before transferring the industrial control system to normal operation mode
Application Scenarios and Features
- Automax PLC System Low-Voltage Power Supply Core Upgrade: Deployed in legacy Reliance Automax PLC systems, the 24V DC / 10A high-current stable output performance meets the power supply requirements of all I/O modules and field sensors, no extra low-voltage power conversion module required
- Harsh Industrial Environment Low-Voltage Control Power Supply: Used in metallurgical rolling mill, papermaking and automotive production lines, the multi-level protection design and wide operating temperature range ensure the module operates stably for a long time in harsh industrial environments
- GV3000/SE VFD Control Loop Power Supply: Applied in Reliance GV3000/SE series variable frequency drive systems, providing stable power supply for the VFD control loop and signal processing circuits, effectively avoiding VFD misoperation caused by power supply fluctuation
- Legacy Reliance Control System Modernization: Acts as the official drop-in replacement for older 0-57C402-C series power supply modules, preserving all existing power wiring and system configuration to minimize production line downtime during hardware replacement
- General Industrial Automation 24V DC Power Supply Expansion: Provides a convenient high-stability 24V DC power supply solution for industrial control systems, no extra power transformation hardware required
Frequently Asked Questions
- Q: My module reports “No Output” fault after installation, what is the most common root cause?
A: 90% of this fault is caused by improper input voltage selection. First confirm the module’s 115/230V AC input selection switch is set correctly, matching the actual industrial control cabinet power supply voltage. - Q: Can I replace an older 0-57C402-C unit with this new unit directly without reconfiguration?
A: Yes, the 0-57C402-C is fully pin-compatible and functionally identical to all earlier revisions, you can perform a direct drop-in replacement without any system power configuration modification. - Q: What is the rated output specification of this module?
A: The 0-57C402-C supports 24V DC / 10A stable continuous output, with voltage stabilization accuracy ≤±0.2%. - Q: What protection functions does this module have?
A: The 0-57C402-C is equipped with overcurrent protection, overvoltage protection, overheating protection and short-circuit automatic recovery function, effectively protecting the rear-end industrial control equipment.