Description
SIEMENS MOORE 16137-151 — APACS+/QUADLOG M-Bus (Modulbus) “A” Side Cable, 4 Meter, Shielded Bus Interconnect for the Moore DCS

16137-151
Brand & Model Title
Siemens Moore (Moore Products Co. heritage) 16137-151 — APACS+/QUADLOG Cable, M-Bus “A” Side, 4 m, Shielded Pre-Terminated Module Bus Cable for Advanced Control Module (ACM) / Modulbus Interface (MBI) Links
The 16137-151 is not a module or a rack — it is a factory-built, pre-terminated cable assembly of the Moore APACS+/QUADLOG bus architecture. In the official Moore catalog decode, the 16137-14x/15x block is organized in strict A/B–length triplets: 16137-145/146/147 = I/O Bus “A” at 4/15/30 m; 16137-148/149/150 = I/O Bus “B” at 4/15/30 m; 16137-151/152 = M-Bus “A” at 4 m and 15 m; and 16137-153/154 = M-Bus “B” at 4 m and 15 m. So the 16137-151 is specifically the 4-meter “A” (primary) channel M-Bus cable, the physical link carrying module-bus traffic between APACS+/QUADLOG racks and interface hardware, with its redundant counterpart being the 16137-153 on the “B” side.
Main Technical Specifications (per the Moore/Siemens 16137 cable catalog decode)
| Parameter | Value |
|---|---|
| Product type | Pre-terminated shielded bus cable assembly (passive interconnect) |
| Platform | Moore APACS+ and QUADLOG distributed control systems |
| Function | M-Bus (Modulbus / Management Bus) “A” side signal transmission |
| Length | 4 m (16137-152 = 15 m “A” version; 16137-222 = 2.5 m “A” version) |
| Channel designation | A side (primary) — redundant pair is the B side 16137-153 (4 m) / 16137-223 (2.5 m) |
| Connectors | OEM keyed/polarized high-density bus connectors, factory-terminated (mis-mate protected) |
| Cable construction | Shielded, impedance-matched to the APACS+ bus specification; flame-retardant industrial jacket with strain relief |
| Termination hardware | M-Bus “A” termination plug 16137-173 (B side: 16137-176) required at physical bus ends |
| Related bus cables | I/O Bus “A” 16137-145/146/147; I/O Bus “B” 16137-148/149/150; M-Net drop cables 16137-68/69 (6 m), 16137-78/79 (1 m) |
| Weight | ~0.1–0.5 kg (cable assembly, supplier-reported) |
| Origin | United States (Moore Products OEM manufacture) |
| Condition in trade | Discontinued/legacy — new-surplus, unused and tested-used stock via spare-part channels |
Typical Applications
- APACS+/QUADLOG module-bus interconnect — linking ACM controllers to MBI/M-NET interface hardware and I/O nests within a cabinet or across adjacent cabinets (4 m span)
- Redundant bus architectures — installed as the “A” channel with a matched 16137-153 “B” cable, providing physically and logically separate paths for hot-standby control
- Cabinet refurbishment and rack swaps — re-cabling after 16114-series MODULERAC chassis replacement, where the original bus cable is damaged, pin-bent or jacket-cracked
- Legacy system life extension — keeping petrochemical, power, pulp & paper and water-treatment APACS+ installations running when OEM cable supply has ended
- Phased migrations — retaining the M-Bus physical layer while communication modules are upgraded at the host level
Related News & Events
- Catalog structure is the key verification tool: the 16137 block follows a rigid pattern (A/B side × 4/15/30 m), so the part number itself encodes side and length — a fact most reseller pages obscure. Cables in this series are also sold as “kits” (e.g., 16137-172A/175A MBI side cable kits, 16137-186/187 MBI extension cables at 150 m), which are not interchangeable with the bare 4 m bus cable.
- Market caution — fabricated listings: this reference is mislabelled broadly, most notably as a “Yokogawa 16137-151 high-precision industrial measurement and process control module” with generic DCS marketing text. Other pages describe the family as “Yokogawa communication cables” merged with Siemens references. The authoritative identity is the Moore APACS+/QUADLOG M-Bus A 4 m cable under Siemens/Moore part control.
- Heritage context: Moore Products’ APACS+ and QUADlog platforms passed to Siemens in 2003 and QUADlog technology was also licensed into Yokogawa ProSafe-PLC — which is why these cables surface under Siemens, Moore and occasionally Yokogawa labels in surplus catalogs. No public datasheet exists; the part-number decode and APACS+ system manuals are the reference standard.
- Field engineering notes in circulation: always install the A and B cables as a matched pair from the same series; fit termination plugs (16137-173 / 16137-176) at the physical bus ends or the bus will fault intermittently; respect bend radius and keep the shield bonded per the cabinet grounding scheme; never substitute a longer cable for a shorter one without confirming bus-length and termination rules; after replacement, run a full loop check and monitor bus-error/module-fault alarms for at least 15 minutes before returning loops to automatic.
- Procurement discipline: verify connector type and keying against the installed MBI/ACM port, confirm cable length by measuring the physical run, and demand continuity/insulation test records — a latent cable defect on a control bus manifests as intermittent rack faults that are expensive to diagnose.