Schneider Electric 140EHC10500 — Modicon Quantum High-Speed Counter Module, 5 Channels, 8 Inputs / 8 Outputs, up to 100 kHz

Summary: The 140EHC10500 is Quantum’s 5-channel high-speed counter module, counting pulses up to 100 kHz from incremental encoders in four configurable modes (event, differential, repeating, rate), with 8 setpoint-triggered FET outputs for scan-independent local control — the standard Quantum solution for speed, length, and flow measurement in high-speed process and motion applications.

Category: Brand:

Description

Schneider Electric 140EHC10500 — Modicon Quantum High-Speed Counter Module, 5 Channels, 8 Inputs / 8 Outputs, up to 100 kHz

140EHC10500

Main Technical Specifications

Parameter Value
Brand / Manufacturer Schneider Electric
Range Modicon Quantum automation platform
Product type High-speed counter module
Counter channels 5 independent channels
Inputs 8 counter inputs
Counting frequency 100 kHz at 5 V DC (RS-422 differential); 20 kHz at 24 V DC
Counting input type Discrete incremental counter (A/B/Z incremental encoders, PNP/NPN pulse generators)
Counting input voltage / current Max 30 V DC; 7 mA per counter input
Discrete input current / thresholds 5 mA; ON: 15–30 V, OFF: 3–5 V (single-ended, 24 V REF)
Outputs 8 discrete outputs, solid-state FET type
Output voltage 20–30 V DC (ON); 0 V (OFF)
Output load current 0.21 A; leakage ≤0.1 mA (OFF)
Addressing 12 input words + 12 output words
Data format 32-bit (max 2,147,483,647) or 16-bit (65,535)
Bus current requirement 250 mA
External power 19.2–30 V DC
Mounting Standard Quantum backplane (rack)
Operating temperature 0…60 °C
Protection Channel-to-bus insulation 500 Vrms; surge suppression
Weight ~0.3 kg

 

Operating Modes (configured in Unity Pro / EcoStruxure Control Expert)

  1. 32-bit event counter — on one or all channels, with no dedicated latch/timing-output mode
  2. 32-bit differential counter — uses two channels per function; reports the difference between two count values (up to 2 differential counters)
  3. 16-bit repeating counter — counts repeatedly upon reaching a setpoint, on one or all channels
  4. 32-bit rate counter — samples a rate over a configurable interval of 1 s or 100 ms

The 8 on-board FET outputs can each be triggered by a specific setpoint, enabling local fast-reacting control independent of the CPU scan. Count values are transferred to the CPU at every scan, with asynchronous updates possible when mounted in the local rack.

 

Typical Applications

  • Motion & positioning — incremental encoder input (5 V RS-422 differential or 24 V single-ended) for length measurement, cut-to-length lines, and servo/stepper position feedback
  • Speed monitoring — turbine or motor RPM measurement via the rate-counter mode
  • Production counting — high-speed product counting on bottling, packaging, and assembly lines
  • Flow totalization — pulse-output flowmeter integration in oil & gas, chemical, and water industries
  • Fast local interlocks — setpoint-triggered FET outputs react without waiting for the PLC scan cycle

 

Usage Notes & Companion Products

  • Accepts incremental encoders only — not absolute encoders; keep encoder pulse frequency ≤100 kHz.
  • Requires Quantum rack/backplane (e.g., 140XBP01000), power supply (140CPS11420), a Unity CPU (e.g., 140CPU65150/65160), and terminal block 140XTS00200.
  • Pairs naturally with 140DRA84000 (relay DO) for valve/actuator drive and 140DAI74000 (DI) for field switch inputs.
  • The module is out of production; procurement is typically from new-surplus stock — plan spares for long-life legacy Quantum installations.