Bently‑Nevada 3500/04 Mixed Internal‑Barrier I/O Assembly (135489‑04 + 136703‑01 + 136711‑01 + 136711‑02 + 137110‑01)

Warranty: 365 days
Quality: Original module
Condition: New / Used
Warehouse: Spot
Delivery time: Shipped in 3 days after payment
WhatsApp:+86 18030274832
Mailbox:Edith@massive-plc.com

Category: Brand:

Description

Bently‑Nevada 3500/04 Mixed Internal‑Barrier I/O Assembly

(135489‑04 + 136703‑01 + 136711‑01 + 136711‑02 + 137110‑01)

135489‑03

135489‑03

Bill of Components Overview

Part Number Module Description Matching Front Monitor
135489‑01‑04 4‑Ch Proximitor Internal‑Barrier I/O (Internal Termination) 3500/40M Proximitor Monitor
136703‑01 2‑Ch Tachometer Internal‑Barrier I/O (Internal Termination) 3500/50 Tachometer Monitor
136711‑01 6‑Ch Temperature Internal‑Barrier I/O (Internal Termination) 3500/60 Temperature Monitor
136711‑02 6‑Ch Temperature‑with‑Recorder Internal‑Barrier I/O (Internal Termination) 3500/61 Temperature Monitor with Recorder Outputs
137110‑01 6‑Ch Process‑Variable Internal‑Barrier I/O (Internal Termination) 3500/62 Process Variable Monitor
138257‑01 Mandatory Internal‑Barrier Earthing I/O Module System‑level common safety ground reference

 

Product Description

This combined internal‑barrier I/O assembly is a full‑set rear‑plug‑in daughter‑board suite for Bently‑Nevada 3500 rack 3500/04 intrinsically‑safe system. Each individual rear I/O board pairs with its corresponding front‑side monitor main board, providing integrated energy‑limiting intrinsic‑safety circuits and built‑in screw‑type internal field‑wiring terminations for sensors installed in explosive‑classified hazardous zones.

  • 135489‑04: 4‑channel proximity‑only barrier I/O for 3300‑XL eddy‑current probes, measuring shaft radial‑vibration, thrust‑position and differential‑expansion signals from hazardous‑area proximity transducers.
  • 136703‑01: 2‑channel tachometer barrier I/O, interfaces proximity probes or magnetic‑pickup speed sensors for shaft rotational‑speed, acceleration and rotation‑direction monitoring.
  • 136711‑01: 6‑channel temperature barrier I/O, accepts RTD / thermocouple inputs for bearing‑metal and process‑temperature measurement.
  • 136711‑02: 6‑channel temperature barrier I/O with recorder‑signal conditioning for 3500/61 monitor, supports local 4‑20 mA recorder outputs for temperature loops in hazardous zones.
  • 137110‑01: 6‑channel process‑variable barrier I/O, interfaces 4‑20 mA field transmitters for casing‑pressure, differential‑pressure and other analog process‑variable signals in classified areas.

All modules draw operating power and digital communication via 3500 rack backplane; no standalone power supply. The whole barrier suite shares low‑impedance safety ground reference from mandatory 138257‑01 earthing module, which guarantees intrinsic‑safety certification validity for all hazardous‑area signal loops. This integrated‑barrier solution eliminates requirement for external Zener barrier cabinets and reduces field‑wiring complexity. No single I/O module can operate independently without matching front monitor board and system barrier earthing module.

 

Technical Specifications (Common for whole assembly; per‑channel differences noted)

 

Item Specification
Product Family 3500/04 Internal Intrinsically‑Safe Barrier System
Form Factor Full‑height rear‑side plug‑in daughter‑boards, install behind corresponding front‑monitor slots
Termination Type Internal built‑in screw terminal blocks (no external termination block required)
Safety Certification Class I Div 2 / ATEX system‑level intrinsic safety (valid only with matched transducers + 138257‑01 earthing module)
Backplane Interface Power & data communication from 3500 rack backplane
Operating Temperature 0 °C ~ +65 °C (32 °F ~ +149 °F)
Storage Temperature ‑40 °C ~ +85 °C (‑40 °F ~ +185 °F)
Relative Humidity 5‑95 % RH, non‑condensing
Single‑module dimension 241.3 mm × 24.4 mm × 163.1 mm (9.50 in × 0.96 in × 6.42 in)
Single‑module weight 0.46 kg (1.01 lbs)
Product Status Discontinued OEM production, aftermarket spare‑part only

Per‑module channel count:

  • 135489‑04: 4 channels (proximity only)
  • 136703‑01: 2 channels (tach / magnetic pickup)
  • 136711‑01: 6 channels (RTD / TC temperature)
  • 136711‑02: 6 channels (temperature with recorder output)
  • 137110‑01: 6 channels (4‑20 mA process variable)
136719-01

136719-01

Key Features & Benefits

  1. Full‑range hazardous‑zone signal coverage: One assembly supports proximity vibration, shaft‑speed, bearing‑temperature and process‑variable measurements; covers most typical TSI monitoring points for rotating machinery installed within explosive classified locations.
  2. Integrated intrinsic‑safety barrier plus internal termination: Energy‑limiting safety circuit and field‑wiring screw terminals are integrated onto each rear‑mounted I/O board. External Zener‑barrier hardware is eliminated; cabinet layout and field installation workload are greatly reduced.
  3. System‑level certified intrinsic safety: When assembled with matching Bently‑Nevada transducers and mandatory 138257‑01 barrier earthing module, the complete stack meets ATEX / Class I Div 2 safety requirements. Improper earthing will invalidate hazardous‑area certification.
  4. Mixed‑module coexistence capability: Internal‑barrier I/O modules and standard non‑barrier I/O modules can co‑exist in one single 3500 rack, supporting mixed safe‑area and hazardous‑area sensor points within one machinery‑protection cabinet.
  5. Hot‑swap maintenance support: Each rear‑side barrier I/O module supports powered‑on hot‑swap replacement; remaining monitor‑channel protection functions stay active during module exchange, on condition that barrier earthing continuity is maintained.
  6. Drop‑in backward compatibility: Fully compatible with legacy 3500 series monitor main boards, rack firmware, RIM and power‑supply assemblies; straightforward spare‑part swap‑out for existing 3500‑series internal‑barrier retrofit and repair projects.

 

Application Fields

  • Combined‑cycle power‑generation plant machinery‑protection racks for steam turbines, gas turbines and centrifugal compressors, where proximity, speed, temperature and process‑variable sensors are installed inside ATEX / Class I Div 2 hazardous compartments.
  • Petrochemical refineries and natural‑gas processing facilities critical rotating‑equipment TSI cabinets, multi‑parameter monitoring for shaft vibration, thrust‑position, rotational‑speed, bearing‑metal temperature and casing process‑variables from explosive‑risk field locations.
  • Legacy‑system retrofit and spare‑part replacement for existing 3500 racks configured with multi‑type internal‑barrier hazardous‑area signal loops.

 

Related Recommended Products

  • 138257‑01: Mandatory Internal‑Barrier Earthing I/O Module (must‑install for whole barrier system)
  • 3500/40M: Front‑side Proximitor Monitor (matches 135489‑04)
  • 3500/50: Front‑side Tachometer Monitor (matches 136703‑01)
  • 3500/60: Front‑side Temperature Monitor (matches 136711‑01)
  • 3500/61: Front‑side Temperature‑with‑Recorder Monitor (matches 136711‑02)
  • 3500/62: Front‑side Process‑Variable Monitor (matches 137110‑01)
  • 3500/20 (125744‑01): TMR Rack Interface Module for rack‑level communication, event logging and system diagnostics
  • 3500/25: Keyphasor timing‑reference module for shaft‑phase‑angle measurement
  • 3500/15 series: Rack power‑supply assemblies for 3500 machinery‑protection rack
  • 3300‑XL proximity probes, RTD / TC sensors, 4‑20 mA transmitters: Matched hazardous‑area‑approved field transducers

 

Installation and Maintenance

Installation

  1. Prior to installing any barrier I/O modules, confirm 138257‑01 barrier earthing module is correctly seated and rack protective‑earth connection is securely terminated. Improper earthing invalidates intrinsic‑safety certification for all hazardous‑area signal loops.
  2. Insert each barrier I/O daughter‑board into the dedicated rear‑slot directly behind its corresponding front‑side monitor main board; ensure complete and firm connector engagement with rack backplane.
  3. Wire hazardous‑area field sensors / transmitters directly onto built‑in screw terminals of each barrier I/O module. Strictly follow maximum allowable cable capacitance‑inductance parameters defined in official Bently‑Nevada 3500 Internal‑Barrier Manual (Doc 141495) to maintain intrinsically‑safe‑loop compliance.
  4. Complete rack configuration work in 3500 Rack Configuration Software; enable internal‑barrier function and select corresponding sensor‑type parameters for each monitor channel.
  5. After power‑on, verify health status for every I/O module; inspect rack event log for barrier‑fault, ground‑fault or loop‑fault diagnostic alarms.

Important Note: None of these barrier I/O modules can work as standalone hardware. Each rear barrier I/O must pair with its dedicated front‑monitor main board. The entire barrier suite depends upon 138257‑01 earthing module for safety‑ground reference.

Maintenance

  1. Perform periodic visual inspection: check rear‑module terminals, connectors and barrier earthing bus for corrosion, dust accumulation and loose wiring connections.
  2. Regularly review rack event log for barrier‑fault, ground‑fault or loop‑fault alarms. Troubleshoot and resolve field‑cable‑insulation or transducer faults promptly once diagnostics appear.
  3. Hot‑swap replacement is permitted while rack remains powered‑on. After module exchange, re‑verify protective‑earth continuity and clear fault alarms.
  4. Avoid mechanical shock, moisture and conductive contamination to rear‑side printed‑circuit assemblies during module handling and replacement.
  5. Refer to official document 141495 (3500 Internal‑Barrier System Operation & Maintenance Manual) for full hazardous‑area installation constraints, loop‑parameter limits and detailed fault‑troubleshooting guidance.