Description
YOKOGAWA 16114-500 — MODULERAC Module Card Rack for QUADlog / ProSafe-PLC Safety Systems (Siemens Cross-Ref A5E002710416)

16114-500
Brand & Model Title
Siemens Moore (Moore Products Co. heritage) 16114-500 — MODULERAC/MODULRACK Module Card Rack with 24 V DC Power Bus, for QUADlog and Yokogawa ProSafe-PLC Safety Controller Systems (Siemens cross-reference: A5E002710416; slot variants 16114-500/4, 16114-500/6)
Like its sibling 16114-171, the 16114-500 is not an I/O card or processor — it is the passive module card rack of the Moore QUADlog safety platform. Its distinct role: after Siemens acquired Moore Products (2003), the QUADlog critical-process safety PLC was also licensed into Yokogawa Industrial Safety Systems (YIS) as the ProSafe-PLC safety system — which is why this rack circulates under both “Siemens Moore” and “Yokogawa” branding. The chassis provides module mounting, backplane interconnection and dual 24 V DC power-bus distribution (max 12 A per bus, redundant-supply capable) for the ProSafe/QUADlog controller and critical I/O modules.
Main Technical Specifications (compiled from convergent supplier documentation — verify per nameplate)
| Parameter | Value |
|---|---|
| Product type | Module card rack / power-bus backplane chassis (passive safety-system component) |
| Platform | Moore QUADlog / Yokogawa ProSafe-PLC safety systems (APACS family architecture) |
| Siemens cross-reference | A5E002710416 |
| Slot variants | 16114-500/4 (4-slot), 16114-500/6 (6-slot) — suffixes are not interchangeable |
| Power bus | 24 V DC; maximum ~12 A per bus; supports redundant power-supply configuration; reverse-polarity protection reported |
| Compatible modules | PSCDM024DCBAN (CDM — Critical Discrete Module, 24 V DC), PSCCM24AAN (critical analog module), ProSafe/QUADlog controller and I/O cards |
| Hazardous-location rating | Class I, Division 2, Groups A, B, C & D (per module documentation) |
| Ambient temperature | Max 60 °C |
| Mounting | 19-inch/cabinet rack installation; robust vibration-resistant chassis |
| Origin | United States (Moore Products Co. heritage) |
| Condition in trade | Discontinued/legacy — supplied as new-surplus or tested units through spare-part channels |
| ⚠️ Caveat | No public Siemens/Yokogawa datasheet for this rack; confirm slot count, bus ratings and revision against the physical nameplate and the ProSafe-PLC/QUADlog system manual |
Typical Applications
- ProSafe-PLC safety instrumented systems (SIS) — mounting and powering the critical I/O modules of Yokogawa YIS safety platforms in refineries, LNG and petrochemical units
- QUADlog critical-process control — Moore/Siemens QUADlog installations requiring rack-level replacement without stranding the proprietary PSC-series module population
- Class I Div 2 hazardous cabinets — rack documented for Groups A–D hazardous-location installation
- Safety-system lifecycle spares — one verified rack chassis protects an entire rack of proprietary critical I/O cards that fit no other platform
Related News & Events
- Dual-brand lineage explained: QUADlog was Moore Products’ TMR-critical safety PLC within the APACS family; after the 2003 Siemens acquisition it was also branded into Yokogawa’s ProSafe-PLC safety offering — hence listings labeled “Yokogawa 16114-500” and “Siemens Moore 16114-500” describe the same hardware. Today both platform lines are legacy: QUADlog/APACS+ is retired in favor of Siemens PCS 7, and Yokogawa’s current safety line is ProSafe-RS.
- Siemens cross-reference confirmed: the A5E002710416 number attached to this rack is a Siemens material reference, consistent with the QUADlog-era part transfer — useful when ordering against Siemens plant BOMs.
- Market caution — heavy mis-listing: this reference attracts fabricated identities including “Yokogawa CENTUM VP/CS3000 redundant power supply 24 VDC/2.1 A, N+1, hot-swap, MTBF 300,000 h”, “digital input module”, “communication interface module”, “I/O module with ±0.01% accuracy”. None of these describe a passive rack. The consistent convergent identity is the QUADlog/ProSafe-PLC MODULERAC card rack with 24 V DC / 12 A power bus.
- Procurement discipline: match the exact slot suffix (/4, /6) to the cabinet; a failed rack disables the full safety-I/O population simultaneously, so verified stock with connector inspection (pin corrosion, power-rail continuity) and revision traceability is essential; rack swaps must follow SIS maintenance procedure with proper bypass management and proof-testing afterward.
- Field engineering notes: audit the redundant 24 V DC supplies while the rack is depopulated — marginal supplies are the most common misdiagnosed “rack fault”; confirm PSCDM024DCBAN/PSCCM24AAN module seating and firmware/revision compatibility of the safety controller before returning the SIS to service.