Description
SIEMENS MOORE 16137-223 — APACS+ / QUADLOG M-Bus “B” Side Cable, 2.5 Meter, Redundant-Channel Module Bus Interconnect

16137-223
Brand & Model Title
Siemens Moore (Moore Products Co. heritage) 16137-223 — APACS+ / QUADLOG Cable, M-Bus “B” Side, 2.5 m, Shielded Pre-Terminated Module Bus Cable Assembly (Redundant Channel, Supersedes 16137-158)
The OEM spare-part catalogue entry reads “APACS+/QUADLOG CABLE, M-BUS B, 2.5M” — the 2.5-metre redundant (“B”) channel of the Moore APACS+ / QUADLOG Module Bus. It is the direct counterpart of the 16137-222 (“A” side) and the short-span alternative to the 4 m 16137-153. Critically, at least one European distributor record carries the note “M-BUS CABLE B (WAS-158)” , which resolves a long-standing catalogue ambiguity: the 16137-158 (the legacy 2 m / 6.6 ft Moore “M-Bus B” assembly) has been superseded by the 16137-223 at 2.5 m. If your as-built documentation says 16137-158, the number to order today is 16137-223.
Main Technical Specifications
| Parameter | Value |
|---|---|
| Product type | Pre-terminated shielded bus cable assembly (passive interconnect) |
| Function | M-Bus (Module Bus) “B” side — redundant channel |
| Platform | Moore APACS+ and QUADLOG DCS |
| Length | 2.5 m (8.2 ft) |
| Primary partner | 16137-222 — M-Bus “A” side, 2.5 m |
| Supersedes | 16137-158 — M-Bus “B”, 2 m / 6.6 ft (legacy Moore number) |
| Longer equivalent | 16137-153 (M-Bus B, 4 m) · 16137-154 (M-Bus B, 15 m) |
| Bus-end terminator | 16137-176 (M-Bus “B” termination plug); “A” side uses 16137-173 |
| Connectors | OEM keyed / polarised, factory crimped, B-side keying distinct from A-side |
| Cable construction | Shielded, impedance-matched; flame-retardant jacket, moulded strain relief |
| Identification codes | EAN / GTIN 4016169407549; tariff 85444290; generic code SIEMNOP; distributor MPN “UPH:16137-223” |
| Shipping weight | ~1.25 kg (distributor pack); carton weights quoted vary widely by reseller |
| Lifecycle | Discontinued by Siemens — surplus / refurbished only; back-order lead times of 3–4 weeks reported |
| Indicative price | ≈ AU80 / US50–110 for tested surplus; grey-market new-in-box considerably higher |
Typical Applications
- Redundant bus installation — fitted as the “B” channel with a matched 16137-222 “A” cable so the module bus survives the loss of either path; the two routes are deliberately separated physically, not equalised in length
- Short in-cabinet spans — the 2.5 m length dresses cleanly inside a MODULERAC cabinet where a 4 m cable would leave an excess loop
- IEM / I/O Extension Module and engineering-station drops — short hops from a Modulrac to an adjacent IEM or an MBI-equipped workstation
- Replacing a 16137-158 during refurbishment — same function, 0.5 m longer, so re-check the cable route and bend radius before fitting
- Fault recovery — swap-out of a cable with a cracked jacket, bent pin or fatigued crimp that presents as a latched MBUS B fault
- Legacy life extension in refining, petrochemical, power, pulp & paper and water treatment pending migration to SIMATIC PCS 7
Related News & Events
- The supersession note is the most useful fact on the internet about this part. “M-BUS CABLE B 2M (WAS-158)” on a UK distributor page, together with EAN 4016169407549, is the only machine-verifiable identity trail in a market saturated with invented copy. Note the internal tension in that same record — title says 2.5M, description says 2M — which is exactly the legacy-number-versus-current-number confusion the “WAS” note is there to resolve. Order by 16137-223 / EAN 4016169407549 and measure the run.
- Fabricated listings are the norm. The top results present this as a “Yokogawa” communication cable; one Chinese reseller page even states the Yokogawa attribution, then contradicts it two paragraphs later with “available product records associate 16137-223 with Siemens Moore Products”. Other pages invent connector types, jacket polymers, IP ratings and CE/UL certification. Treat every one of those specifications as fiction — there is no Siemens datasheet for this part.
- A-side and B-side are not interchangeable. The connectors are keyed and the two paths are wired differently. Sibling-part confusion inside the 2.5 m block is common: 16137-222 (M-Bus A), 16137-223 (M-Bus B), 16137-224 (I/O Bus A), 16137-225 (I/O Bus B) — four different cables, four different functions, all “2.5 m APACS cable” in a scraped listing.
- Termination is not optional. Both physical ends of each path need the correct plug — 16137-176 for the B side. A missing or one-turn-loose terminator produces intermittent faults that look exactly like a cable defect, and the ACM will latch the fault rather than clear it.
- Latched fault behaviour: an APACS MBUS fault is held in the controller’s diagnostic logic across hot-insert/hot-remove and station connections. Replacing the B cable restores the physical layer but does not clear the alarm; recovery requires a controlled power-down/power-up of the redundant ACM pair. Plan the swap for an outage, verify both ACMs hold steady green for five minutes, and run a loop check before returning loops to auto.
- Availability signal: a mainstream UK distributor currently shows this part as back-order at 26–27 days, with only small quantities in secondary stock (a handful of units at one US surplus house, two at an Australian one). For a cable that costs tens of dollars, holding two spares is cheap insurance against a multi-week outage on a controller pair.
- Lifecycle: APACS+ / QUADLOG is fully discontinued and out of Siemens support; QUADlog was also licensed into Yokogawa ProSafe-PLC, which is the root of the recurring Yokogawa mislabelling. Weidmüller publishes an adapter-rack migration route that preserves existing field terminations.