Allen‑Bradley 1746‑A7 SLC 500 7‑Slot Modular Chassis

Recommended Related Part Numbers

  • 1746‑P4: SLC 500 power supply
  • 1747‑L541 / 1747‑L552: SLC 500 processors
  • 1746‑IB16: 16‑point digital input module
  • 1746‑OB16: 16‑point digital output module
  • 1746‑NI4: 4‑channel analog input module
  • 1746‑NO4I: 4‑channel analog output module
  • 1746‑A10: 10‑slot SLC chassis
Category: Brand:

Description

Allen‑Bradley 1746‑A7 SLC 500 7‑Slot Modular Chassis

 

Meta Description

Original Allen‑Bradley 1746‑A7 SLC 500 7‑slot modular backplane chassis for SLC 500 processor and I/O modules, discontinued by Rockwell, limited stock for legacy spare parts. We operate 86 shared warehouses globally, so it may take several hours to deliver an accurate quotation; thank you for your understanding, and we will handle your inquiry promptly.

1746-A7

Product Brief Introduction

The 1746‑A7 is a 7‑slot passive backplane chassis for the Allen‑Bradley SLC 500 modular PLC platform. It provides mechanical mounting and backplane power & signal interconnection for SLC processors, digital I/O, analog I/O and communication modules. The power supply attaches to the left side of the chassis, and modules slide into slots with simple latching. Up to three SLC chassis can be daisy‑chained together to expand the local I/O system. Rockwell officially discontinued the 1746‑A7 effective March 31, 2024 with no direct factory replacement. Stock is limited and reserved for maintenance, repair and retrofitting of existing SLC 500 automation systems. We operate 86 shared warehouses globally, so it may take several hours to deliver an accurate quotation; thank you for your understanding, and we will handle your inquiry promptly.

 

Main Technical Specifications

  • Part Number: 1746‑A7
  • Manufacturer: Allen‑Bradley / Rockwell Automation
  • Platform: SLC 500 Modular Hardware Style
  • Slot Count: 7 slots
  • Function: Passive backplane chassis for processor, I/O and communication modules
  • Mounting: Panel back‑mounting
  • Cooling: Natural convection
  • Operating Temperature: 0 °C to +60 °C
  • Storage Temperature: −40 °C to +85 °C
  • Relative Humidity: 5%–95%, non‑condensing
  • Certifications: UL, cULus, CE
  • Lifecycle Status: Discontinued, End of Sale: March 31, 2024; no official direct replacement
  • Warranty: 1 year
  • Expansion: Daisy‑chain up to 3 chassis (max 30 local slots)
  • Compatible Power Supplies: 1746‑P1, P2, P3, P4, P5, P6

 

Quality Control Procedure

Each 1746‑A7 legacy chassis undergoes our dedicated spare inspection workflow. We inspect the metal housing, backplane PCB, gold contacts, mounting lugs and locking latches for corrosion, bent pins or physical damage. Continuity testing verifies all power and signal traces on the backplane. We test fit with genuine SLC power supplies and I/O modules to confirm stable backplane communication. Units that pass all checks are packed with anti‑static shielding, and test records are retained for traceability. Please note if you submit a quote request: We operate 86 shared warehouses globally, so it may take several hours to deliver an accurate quotation; thank you for your understanding, and we will handle your inquiry promptly.

 

FAQ

Q: What is 1746‑A7 used for? A: It is a 7‑slot backplane rack that holds SLC 500 CPU, digital, analog and communication modules and distributes backplane power and signals.

Q: Is this chassis still in production? A: No, Rockwell discontinued the 1746‑A7 on March 31, 2024. Available stock is limited surplus inventory only.

Q: Does the 1746‑A7 include a power supply? A: No, the power supply is sold separately and mounts on the left end of the chassis.

Q: Can I install a processor inside this chassis? A: Yes, the SLC 500 processor occupies the leftmost slot of the 1746‑A7.

Q: Can I connect multiple SLC chassis together? A: Yes, up to three SLC chassis can be interconnected to expand the local I/O capacity.

Q: When will I receive my quotation? A: We operate 86 shared warehouses globally, so it may take several hours to deliver an accurate quotation; thank you for your understanding, and we will handle your inquiry promptly.

 

Installation & Configuration Guide

Secure the 1746‑A7 to the control panel using its mounting tabs. Install the matching SLC power supply onto the left end of the chassis. Insert the SLC processor into the first slot, then fit digital, analog or communication modules into the remaining slots. If system expansion is required, connect chassis interconnection cables between linked racks. Wire the input voltage to the power supply and confirm polarity before energising. Use SLC programming software to download logic and verify the processor recognises all I/O modules. Always calculate and stay within the total backplane power budget. Follow Rockwell’s official installation manual and local electrical codes.

 

Relevant News & Events

The SLC 500 platform remains widely deployed in legacy factories, packaging, water treatment and material handling lines. Rockwell’s end‑of‑sale announcement for SLC chassis pushes asset owners to plan migration toward Compact 5000 I/O paired with Logix controllers for new projects. However, demand for original 1746‑A7 and other SLC spare parts stays high for emergency breakdown repair and planned maintenance of running legacy plants.

 

Application Scenarios & Functional Advantages

Typical Use Cases

  • Legacy SLC 500 PLC system spare chassis replacement
  • Mid‑size packaging machine control panel repair
  • Conveyor and material handling system maintenance
  • Water & wastewater treatment legacy control retrofit
  • General factory automation SLC 500 system expansion
  • Spare backup for critical production lines not yet migrated

Key Advantages

  • Balanced 7‑slot layout, ideal for medium‑size SLC stations
  • Simple tool‑free module insertion and removal
  • Supports mixed digital, analog and communication modules
  • Capable of multi‑chassis expansion up to 30 local slots
  • Robust passive backplane design with low failure rate
  • Compact footprint compared to the 10‑slot and 13‑slot variants

 

Recommended Related Part Numbers

  • 1746‑P4: SLC 500 power supply
  • 1747‑L541 / 1747‑L552: SLC 500 processors
  • 1746‑IB16: 16‑point digital input module
  • 1746‑OB16: 16‑point digital output module
  • 1746‑NI4: 4‑channel analog input module
  • 1746‑NO4I: 4‑channel analog output module
  • 1746‑A10: 10‑slot SLC chassis